ABB GJL121 Contactor, 12V Coil, 3-Pole, 20 A, 4 kW 12V, 4 NO, 690V
- RS Stock No.:
- 253-4790
- Mfr. Part No.:
- GJL1213901R0107
- Manufacturer:
- ABB
Subtotal (1 pack of 5 units)*
PHP29,991.10
(exc. VAT)
PHP33,590.05
(inc. VAT)
FREE delivery for orders over ₱3,000.00
Stocked by manufacturer
- Ready to ship from May 14, 2026
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per Unit | Per Pack* |
|---|---|---|
| 5 + | PHP5,998.22 | PHP29,991.10 |
*price indicative
- RS Stock No.:
- 253-4790
- Mfr. Part No.:
- GJL1213901R0107
- Manufacturer:
- ABB
Specifications
Technical data sheets
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | ABB | |
| Product Type | Contactor | |
| Coil Voltage | 12V | |
| Number of Poles | 3 | |
| Contact Voltage | 690V | |
| Contact Current | 20A | |
| Series | GJL121 | |
| Power Rating | 4kW | |
| Function | Reversing Contactor | |
| Mount Type | DIN Rail, Wall | |
| Normal State Configuration | 4 NO | |
| Number of Auxiliary Contacts | 1 | |
| Terminal Type | Screw | |
| Operational Current Ie | 20A | |
| Control Circuit Voltage Uc | 12V | |
| Minimum Operating Temperature | -20°C | |
| Contactor Application | Control Unit | |
| Maximum Operating Temperature | 55°C | |
| Depth | 46.7mm | |
| Standards/Approvals | IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-4-1 | |
| Length | 46.7mm | |
| Width | 58mm | |
| Pole and Throw Configuration | 3P | |
| Select all | ||
|---|---|---|
Brand ABB | ||
Product Type Contactor | ||
Coil Voltage 12V | ||
Number of Poles 3 | ||
Contact Voltage 690V | ||
Contact Current 20A | ||
Series GJL121 | ||
Power Rating 4kW | ||
Function Reversing Contactor | ||
Mount Type DIN Rail, Wall | ||
Normal State Configuration 4 NO | ||
Number of Auxiliary Contacts 1 | ||
Terminal Type Screw | ||
Operational Current Ie 20A | ||
Control Circuit Voltage Uc 12V | ||
Minimum Operating Temperature -20°C | ||
Contactor Application Control Unit | ||
Maximum Operating Temperature 55°C | ||
Depth 46.7mm | ||
Standards/Approvals IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-4-1 | ||
Length 46.7mm | ||
Width 58mm | ||
Pole and Throw Configuration 3P | ||
- COO (Country of Origin):
- DE
ABB GJL121 Series Contactor, 20A Operational Current, 12V Control Circuit Voltage - GJL1213901R0107
This contactor is a Compact electrically operated switching device designed for reversing motor control in commercial, industrial and residential installations. It provides a three-pole switching arrangement for power circuits and is intended for mounting on a DIN rail or directly to a wall. The unit is suited to control circuits running at low control voltages and integrates a single auxiliary contact for signalling or interlock purposes.
Features and Benefits:
• 12V Coil enables low-voltage control circuit compatibility
• 20A operational current supports moderate motor and load switching
• 690V maximum contact voltage for high-voltage distribution use
• 3P configuration allows three-phase reversing control
• Screw terminals provide secure conductor connections
• Conforms to recognised IEC and UL contactor standards
• 20A operational current supports moderate motor and load switching
• 690V maximum contact voltage for high-voltage distribution use
• 3P configuration allows three-phase reversing control
• Screw terminals provide secure conductor connections
• Conforms to recognised IEC and UL contactor standards
Applications
• Suitable for reversing small three-phase motors in plant equipment
• Ideal for motor control panels in light industrial settings
• Used for load switching in residential distribution systems
• Can be used in automation racks mounted on DIN rail assemblies
• Suitable for control circuits requiring an auxiliary signal contact
• Ideal for motor control panels in light industrial settings
• Used for load switching in residential distribution systems
• Can be used in automation racks mounted on DIN rail assemblies
• Suitable for control circuits requiring an auxiliary signal contact
What environmental temperature range can it operate within?
It is rated to function between -20°C and 55°C, permitting use in typical indoor and sheltered outdoor electrical enclosures.
How many auxiliary contacts are available for control signalling?
There is one normally open auxiliary contact provided for status feedback or interlock circuits.
What mounting options exist for secure installation?
The product supports both DIN rail attachment and direct wall mounting to suit panel or enclosure configurations.
What terminals are used for connecting power and control conductors?
Screw-type terminals are provided to accommodate standard wiring practices and ensure reliable clamping.
What power capacity does it manage for motor applications?
It is specified with a power rating of 4 kW, appropriate for small motor and general load switching in three-phase systems.
Related links
- ABB GJL121 Contactor 3-Pole 4 NO, 690V
- ABB GJL121 Contactor 3-Pole 4 kW 12 V 250 V dc, 690V ac
- ABB GJL121 Contactor 3-Pole 3 NO/1 NC 690V ac
- ABB GJL121 Contactor 4-Pole 4 kW 12 V 220V
- ABB GJL131 Contactor 3-Pole 5.5 kW 12 V 690V
- ABB GJL121 Contactor 3-Pole 4 kW 125 V 690V
- ABB GJL121 Contactor 3-Pole 4 kW 48 V 690V
- ABB GJL121 Contactor 3-Pole 1.4 kW 24 V 690V