ABB Jokab, 30 A, 7.5 kW 24V dc

Subtotal (1 unit)*

PHP9,136.67

(exc. VAT)

PHP10,233.07

(inc. VAT)

Add to Basket
Select or type quantity
In Stock
  • 28 unit(s) ready to ship from another location
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units
Per Unit
1 +PHP9,136.67

*price indicative

RS Stock No.:
175-3208
Mfr. Part No.:
1SBL176082R3022 AFS16Z-30-22-30
Manufacturer:
ABB Jokab
Find similar products by selecting one or more attributes.
Select all

Brand

ABB Jokab

Contact Current

30A

Power Rating

7.5kW

Number of Auxiliary Contacts

4

Control Circuit Voltage Uc

24V dc

Operational Current Ie

16A

Contactor Application

Safety

COO (Country of Origin):
FR

ABB Jokab Contactor, 600V AC Contact Voltage Rating, Screw Terminals - AFS Series - 1SBL176082R3022 AFS16Z-30-22-30


Need to constantly flip a system on and off? Help to extend its life cycle with this contactor from ABB Jokab. The fast-acting switch is designed to continuously make or break an electric circuit, so keeps high-current load devices running reliably. Mirror contacts boost the safety stakes by monitoring and instantly reacting to the unit's switched state. A mechanical switching frequency of 3,600 cycles per hour keeps it going at a pace that meets the needs of demanding systems. As this contactor comes with a protective cover, it cuts out the risk of unauthorised manual operation.

• Built-in surge suppression prevents power spikes from damaging equipment

• IP20-rated enclosure that's touch-proof and protected against objects larger than 12mm

• Bright yellow housing makes it quick and easy to identify as a safety device

• Screw terminals hold wires securely, so there's minimal need for re-tightening

Applications


• Commercial and industrial lighting systems

• Water pumps

• Food and beverage industries

• Cold storage facilities

AFS09Z ... AFS38Z contactors are designed for machine safety applications. They are delivered with fixed front-mounted auxiliary contact blocks making them ideal for monitoring and controlling circuits. Mechanically linked and mirror contacts make your system safer. - control circuit with electronic coil interface: - dedicated 24 V DC for direct control by PLC-output ≥ 250 mA, low holding consumption up to 1.7 W - reduced panel energy consumption - mirror and mechanically linked contacts, with front marked symbol, always guaranteeing the right contactor status

Is this contactor energy-efficient?


control circuit with electronic coil interface

dedicated 24 V DC for direct control by PLC-output

Mirror and mechanically linked contacts

Front-mounted auxiliary contact block

Protective cover to prevent manual operation

Minimum switching capacity 12 V / 3 mA

Built-in surge suppression

Yes. With a low power holding consumption of up to 1.7W, you can count on the unit to reduce your control panel energy usage.