Schneider Electric, TeSys Thermal Overload Relay 1 NO/1 NC, 0.23A, 0.36 A F.L.C, 360mA Contact Rating, 2 W, 250 V dc,
- RS Stock No.:
- 372-8981
- Mfr. Part No.:
- LR2K0303
- Manufacturer:
- Schneider Electric
Subtotal (1 unit)*
PHP3,255.21
(exc. VAT)
PHP3,645.84
(inc. VAT)
FREE delivery for orders over ₱3,000.00
In Stock
- 3 unit(s) ready to ship from another location
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per Unit |
|---|---|
| 1 + | PHP3,255.21 |
*price indicative
- RS Stock No.:
- 372-8981
- Mfr. Part No.:
- LR2K0303
- Manufacturer:
- Schneider Electric
Specifications
Technical data sheets
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | Schneider Electric | |
| FLC Motor Rating | 0.23, 0.36A | |
| Product Type | Thermal Overload Relay | |
| Relay Contact Current | 360mA | |
| Mount Type | Direct | |
| Series | TeSys | |
| Pole and Throw Configuration | 3 | |
| Power Rating | 2W | |
| Normal State Configuration | 1 NO/1 NC | |
| Terminal Type | Screw Clamp | |
| Reset Method | Automatic & Manual | |
| IP Rating | IP2X | |
| Number of Auxiliary Contacts | 2 | |
| Width | 45mm | |
| Minimum Operating Temperature | -20°C | |
| Adjustable Current Range | 0.23 to 0.36 A | |
| Maximum Operating Temperature | 55°C | |
| Length | 116mm | |
| Contact Voltage | 690V ac | |
| Standards/Approvals | UL, BS 4941, UKCA, NF C 63-650, IEC 60947, VDE 0660, CSA | |
| Depth | 65mm | |
| Supply Voltage | 690V ac | |
| Control Voltage | 250, 690V dc | |
| Select all | ||
|---|---|---|
Brand Schneider Electric | ||
FLC Motor Rating 0.23, 0.36A | ||
Product Type Thermal Overload Relay | ||
Relay Contact Current 360mA | ||
Mount Type Direct | ||
Series TeSys | ||
Pole and Throw Configuration 3 | ||
Power Rating 2W | ||
Normal State Configuration 1 NO/1 NC | ||
Terminal Type Screw Clamp | ||
Reset Method Automatic & Manual | ||
IP Rating IP2X | ||
Number of Auxiliary Contacts 2 | ||
Width 45mm | ||
Minimum Operating Temperature -20°C | ||
Adjustable Current Range 0.23 to 0.36 A | ||
Maximum Operating Temperature 55°C | ||
Length 116mm | ||
Contact Voltage 690V ac | ||
Standards/Approvals UL, BS 4941, UKCA, NF C 63-650, IEC 60947, VDE 0660, CSA | ||
Depth 65mm | ||
Supply Voltage 690V ac | ||
Control Voltage 250, 690V dc | ||
Schneider Electric LR2K0303
LR2K0303 is a TeSys LRK thermal overload relay from Schneider Electric to be used with a TeSys K contactors. It protects motors 0.06-0.09kW@400V thanks to a thermal range 0.23-0.36A, a tripping class 10A and phase unbalance protection. LR2K0303 is a TeSys LRK thermal overload relay from Schneider Electric for direct mounting on TeSys K contactors. With a thermal setting range 0.23-0.36A, a tripping class 10A and phase unbalance detection, it protects motors 0.06-0.09kW@400V. It provides manual test & reset buttons, automatic reset, trip auxiliary contact and flag indicator. Available worldwide, it is multi-standards certified (IEC, UL, CSA, CCC, EAC, Marine) and Green Premium compliant (RoHs/Reach). Thermal overload protection relay, bimetallic type, with phase unbalance protection (differential). Direct mounting on the bottom terminals of a Tesys contactor LC1K06 to form a compact starter. Light and compact, 45mm wide. Manual control with test & reset buttons, manual / automatic reset selector. Trip signaling with 1NO+1NC auxiliary contacts and trip flag indicator. Can be completed with terminal blocks for separate mounting (LA7K0064).
Schneider Electric Mini Thermal Overload Relays - LR2-K Range
Schneider Electrics K thermal overload relays are adjustable from 0.11 to 11.5 A, they have been predominantly designed for use in applications that require motor protection.
This range of mini thermal overload relays feature compensated and phase failure sensitivity, the range also offers manual and automatic reset. Each overload relay has 3-poles and screw clamp terminals.
Features & Benefits
• Commonly referred to by the range short name - LR2K
• Easy maintenance checks, check the tightening of cables through conducting thermographic testing and checking the mechanical operation of the product through manually operating the test, reset and stop buttons
• Direct mounting under a contactor is achievable
• Standards - IEC 947, BS4941, VDE 0660, NFC63-650
• Standards - CSA, UL, DEMKO, NEMKO, SEMKO, FIMKO, PTB
Applications of a Contactor and Control Overload Relay
• The majority of the time is to protect a motor
• To detect both overload conditions and fault conditions to then announce trip command for a protective device
• To deactivate a device whenever it pulls high current
• Sometimes developed into microprocessor systems and solid-state electronics
Related links
- Schneider Electric 0.16A 230mA Contact Rating 250 V dc,
- Schneider Electric 0.11A 160mA Contact Rating 250 V dc,
- Schneider Electric 0.36A 540mA Contact Rating 250 V dc,
- Schneider Electric 3.7A 5.5A Contact Rating 250 V dc, 690V
- Schneider Electric 1.8A 2.6A Contact Rating 250 V dc, 690V
- Schneider Electric 11.5A 11.5A Contact Rating 250 V dc, 690V
- Schneider Electric 150A F.L.C 75 kW, 32V
- Schneider Electric 630A F.L.C 32V