Fluke 378 FC Clamp Meter, 999.9 A dc 2500 A ac 1000 V dc 1000 V ac CAT III 1000 V, CAT IV 600 V Non-Contact Voltage
- RS Stock No.:
- 220-4446
- Distrelec Article No.:
- 302-16-596
- Mfr. Part No.:
- FLUKE-378 FC/E
- Manufacturer:
- Fluke
- RS Stock No.:
- 220-4446
- Distrelec Article No.:
- 302-16-596
- Mfr. Part No.:
- FLUKE-378 FC/E
- Manufacturer:
- Fluke
Select all | Attribute | Value |
|---|---|---|
| Brand | Fluke | |
| Product Type | Clamp Meter | |
| Resistance Resolution | 10Ω | |
| Maximum DC Current Measurement | 999.9A dc | |
| Maximum AC Voltage Measurement | 1000V ac | |
| Maximum DC Voltage Measurement | 1000V dc | |
| Maximum Resistance Measurement | 60kΩ | |
| Model Number | 378 FC | |
| DC Current Accuracy | ± 2 % rdg + 10 Digits | |
| DC Current Resolution | 100mA | |
| Minimum Operating Temperature | -10°C | |
| AC Current Resolution | 100mA | |
| Resistance Measurement Accuracy | ±1 % rdg + 5 Digits | |
| AC Voltage Accuracy | ±1 % rdg + 5 Digits | |
| AC Voltage Resolution | 1V ac | |
| Maximum Jaw Opening | 34mm | |
| DC Voltage Resolution | 0.1 (≤600.0 V) V;1 (≤1000 V) V | |
| AC Current Accuracy | 2 % | |
| DC Voltage Accuracy | 1 % rdg + 10 Digits | |
| Clamp Meter Type | AC/DC Clamp Meter | |
| Maximum Operating Temperature | 50°C | |
| Height | 47mm | |
| Length | 274mm | |
| Weight | 463g | |
| Width | 86mm | |
| Standards/Approvals | IEC 610102032, IEC 6155713, IEC 610102033, IEC 610101, IEC 60529 | |
| Functions Measured | Current, Voltage | |
| True RMS | Yes | |
| Maximum AC Current Measurement | 2500A ac | |
| Maximum Temperature Measurement | 50°C | |
| Non-Contact Voltage Detector | Yes | |
| Battery Life | 200h | |
| Power Source | Battery | |
| Safety Category Voltage | 1kV, 600kV | |
| Battery Type | AA IEC LR06 | |
| Safety Category Level | CAT III 1000 V, CAT IV 600 V | |
| Select all | ||
|---|---|---|
Brand Fluke | ||
Product Type Clamp Meter | ||
Resistance Resolution 10Ω | ||
Maximum DC Current Measurement 999.9A dc | ||
Maximum AC Voltage Measurement 1000V ac | ||
Maximum DC Voltage Measurement 1000V dc | ||
Maximum Resistance Measurement 60kΩ | ||
Model Number 378 FC | ||
DC Current Accuracy ± 2 % rdg + 10 Digits | ||
DC Current Resolution 100mA | ||
Minimum Operating Temperature -10°C | ||
AC Current Resolution 100mA | ||
Resistance Measurement Accuracy ±1 % rdg + 5 Digits | ||
AC Voltage Accuracy ±1 % rdg + 5 Digits | ||
AC Voltage Resolution 1V ac | ||
Maximum Jaw Opening 34mm | ||
DC Voltage Resolution 0.1 (≤600.0 V) V;1 (≤1000 V) V | ||
AC Current Accuracy 2 % | ||
DC Voltage Accuracy 1 % rdg + 10 Digits | ||
Clamp Meter Type AC/DC Clamp Meter | ||
Maximum Operating Temperature 50°C | ||
Height 47mm | ||
Length 274mm | ||
Weight 463g | ||
Width 86mm | ||
Standards/Approvals IEC 610102032, IEC 6155713, IEC 610102033, IEC 610101, IEC 60529 | ||
Functions Measured Current, Voltage | ||
True RMS Yes | ||
Maximum AC Current Measurement 2500A ac | ||
Maximum Temperature Measurement 50°C | ||
Non-Contact Voltage Detector Yes | ||
Battery Life 200h | ||
Power Source Battery | ||
Safety Category Voltage 1kV, 600kV | ||
Battery Type AA IEC LR06 | ||
Safety Category Level CAT III 1000 V, CAT IV 600 V | ||
- COO (Country of Origin):
- US
Fluke Clamp Meter, 2500A Maximum AC Current Measurement, 1000V Maximum AC Voltage Measurement - FLUKE-378 FC/E
Features and Benefits:
• Measures up to 2500A ac for high current systems
• 1000V capability with CAT III 1000V and CAT IV 600V safety levels
• 34mm jaw opening enables clamping around large conductors
• 0.1A resolution supports fine current measurement detail
• Battery life of 200 h for extended portable use
Applications
• Ideal for testing HV and LV electrical installations
• Used with motor and generator maintenance checks
• Can be used for site electrical safety verification
• Suitable for Rapid on-site voltage presence detection
What voltage ranges can it measure?
How precise are current measurements on this tool?
Which resistance and temperature capabilities are provided?
What environmental conditions can it operate within?
What power source does it use and how long will it run?
Supplied with
• iFlex flexible current probe (18 inches; 48 cm)
• TL224 silicone insulated test leads
• TP175 adjustable length test probes
• AC285 grounding clip (black, quantity one)
• TPAK magnetic hanging kit, with 9 inch (23 cm) hanging strap
• Carrying case
• Quick reference guide
Related links
- Fluke 377 FC Clamp Meter CAT III Non-Contact Voltage Detector
- Fluke 376 FC Clamp Meter CAT IV Non-Contact Voltage Detector
- RS PRO 173 Clamp Meter CAT IV 600 V Non-Contact Voltage Detector
- RS PRO 175 Clamp Meter CAT III 1000 V Non-Contact Voltage Detector
- RS PRO 177 Clamp Meter CAT IV 600 V Non-Contact Voltage Detector
- Fluke 375 FC Clamp Meter CAT IV Non-Contact Voltage Detector
- Fluke 374 FC Clamp Meter CAT IV Non-Contact Voltage Detector
- RS PRO 157B Clamp Meter 1000 A ac 1000 V dc 999.9 V ac CAT IV, CAT III Non-Contact Voltage Detector