ABB Auxiliary Contact, 1 Contact, 1 NO, EF14, Front, 6 A, 690V ac, 1SBN010111R1010 CC4-10

Subtotal (1 unit)*

PHP1,392.03

(exc. VAT)

PHP1,559.07

(inc. VAT)

Add to Basket
Select or type quantity
In Stock
  • Plus 12 unit(s) shipping from April 27, 2026
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units
Per Unit
1 +PHP1,392.03

*price indicative

Bag the Deal of the Season
RS Stock No.:
711-6332
Mfr. Part No.:
1SBN010111R1010 CC4-10
Manufacturer:
ABB
Find similar products by selecting one or more attributes.
Select all

Brand

ABB

Number of Contacts

1

Product Type

Auxiliary Contact

Normal State Configuration

1 NO

Series

EF14

Mount Type

Front

Contact Current

6A

Terminal Type

Screw

Pole and Throw Configuration

1P

Contact Voltage

690V ac

Mechanical Durability

10Mcycles

Operational Current Ie

6A

Rated Insulation Voltage Ui

690V

Mounting Location

Front Side

Minimum Operating Temperature

-40°C

Maximum Operating Temperature

70°C

Standards/Approvals

No

ABB EF14 Series Auxiliary Contact, 6A Contact Current, 690V Contact Voltage - 1SBN010111R1010 CC4-10


This auxiliary contact is a front-mounted, single-pole leading contact Block designed to extend control circuits in industrial contactor and relay assemblies. It connects via screw terminals and is intended for use in standard industrial environments where a normally open contact is required to signal or interlock auxiliary functions.

Features & Benefits


• 6A rated current for Compact control-circuit switching
• 690V insulation rating for high-voltage auxiliary circuits
• Mechanical endurance 10M cycles to reduce maintenance frequency
• Operates from -40°C to 70°C for a wide ambient range
• Screw terminals support up to 2.5 mm² conductor sizes
• 1NO configuration simplifies wiring for single-function schemes

Applications


• Suitable for front-side mounting on AF and NF contactors
• Ideal for signalling circuits in motor control panels
• Used with contactor relays to provide leading-contact feedback
• Can be used for auxiliary interlocks in industrial automation

What Terminal types and conductor sizes are supported?


Connections use screw terminals compatible with rigid or flexi ble conductors up to 2.5 mm², including insulated ferrules as specified for proper electrical contact.

How does the device handle short-time current stresses?


It withstands short-time currents with rated short-time withstand capacities and specified Peak values for 0.1 s and 1 s impulses, suitable for typical contactor switching transients.

What switching frequency can be expected in demanding operations?


The unit is specified for high mechanical and electrical switching frequencies with separate limits for electrical duty and mechanical cycles, enabling frequent operations in control applications.

Which mounting orientation is required for installation?


The Block is designed for front placement on compatible contactor frames, ensuring correct mechanical engagement and electrical alignment.

Standards

UL 508, CSA C22.2 N14