Power Integrations, AC/DC Converter 270 mA, 50V, 50 V 7-Pin, SMD LNK3205G-TL

This image is representative of the product range

Bulk discount available
View bulk pricing options

Subtotal (1 pack of 25 units)*

PHP1,357.25

(exc. VAT)

PHP1,520.00

(inc. VAT)

Add to Basket
Select or type quantity
Stock information currently inaccessible - Please check back later

Units
Per Unit
Per Pack*
25 - 25PHP54.29PHP1,357.25
50 - 75PHP52.661PHP1,316.53
100 - 225PHP50.555PHP1,263.88
250 - 475PHP48.027PHP1,200.68
500 +PHP45.146PHP1,128.65

*price indicative

Packaging Options:
RS Stock No.:
146-4583
Mfr. Part No.:
LNK3205G-TL
Manufacturer:
Power Integrations
Find similar products by selecting one or more attributes.
Select all

Brand

Power Integrations

Maximum Input Voltage

265V ac

Product Type

AC/DC Converter

Maximum Output Voltage

50V

Mount Type

Surface

Pin Count

7

Switching Frequency

66kHz

Maximum Output Current

270mA

Package Type

SMD

Minimum Input Voltage

85V ac

Topology

Flyback

Maximum Duty Cycle

69%

Minimum Operating Temperature

-40°C

Maximum Operating Temperature

150°C

Height

3.68mm

Series

LinkSwitch-TN2

Width

6.6mm

Length

9.83mm

Standards/Approvals

No

Minimum Output Voltage

50V

Supply Current

141μA

Automotive Standard

No

Supports buck, buck-boost and flyback topologiesLow component-count buck converter. Selectable device current limitHigh current limit extends Peak power and maximizes continuous output power. Low current limit allows the use of lowest-cost surface mount buck chokes 66 kHz operation with accurate current limit. Allows the use of low-cost off-the-shelf inductors. Reduces size and cost of magnetics and output capacitor.

Low component-count buck converter

Excellent load and line regulation

Selectable device current limit

66 kHz operation with accurate current limit

Allows the use of low-cost off-the-shelf inductors

Reduces size and cost of magnetics and output capacitor

Frequency jittering reduces EMI filter complexity

Pin-out simplifies PCB heat sinking

Auto-restart for short-circuit and open loop faults

Limits power delivery to 3% of maximum during a fault

Related links