Transformer Core, Ferrite Magnetic, Ferrite Transformer | RS
Recently searched

    Transformer Cores

    Transformers consist of a magnetic circuit commonly referred to as the "transformer core", the purpose of which is to create a pathway around which magnetic fields can flow. To induce voltage between the two input and output windings, this magnetic path is necessary.

    Ferrite Core Transformer

    Transformers use ferrite cores to reduce losses and increase efficiency by reducing losses. In ferrite cores, iron oxide is combined with other metallic elements to form ferrite, a ferromagnetic material. Because ferrite cores have a high magnetic permeability and a low electrical conductivity, they are commonly used in transformers.

    How does the Transformer Ferrite Cores work?

    Transformers use ferrite cores to form magnetic fields. A change in current induces a magnetic field in the primary winding of the transformer, which then magnetizes the secondary winding through the ferrite core. As a result of the change in magnetic field in the core, ferrite cores reduce losses caused by eddy currents and hysteresis losses in transformers.

    Types of transformers ferrite cores

    Different transformer cores are intended to be used with specific kinds of equipment. These include broadband transformers, DC/DC converters, flat transformers, power transformers, reactors, switch mode power supply (SMPS ) transformers, and transmitters.

    In addition to length, depth, and width, transformer ferrite cores also vary in their minimum and maximum operating temperatures. It is important to consider the operating temperature of the equipment that the core will be used in when choosing between cores.

    There are several types of ferrite cores that are used in transformers:

    Manganese Zinc (MnZn)

    In NiZn ferrites, saturation levels are higher and permeabilities are higher. Applications with frequencies less than 5MHz are suitable for these. Inductors up to 70 MHz can also be used with them because of their impedance.

    Nickel Zinc (NiZn)

    Their resistivity is higher than that of MnZn ferrites. The inductors used in these applications are suitable for inductor frequencies above 70 MHz, between 2 MHz and several hundred MHz.

    Sand Dust

    It is ideally suited for use with ferrites only because these Choke Coils have a high frequency.

    Lamination/ Amorphous & Nanocrystalline

    UPS systems, inverters, and welding sets use lamination transformers.

    What is the reason for the transformer cores high demand?

    Transformer cores with ferrites are usually more in demand than those with iron cores, as ferrites have several advantages.

    A ferrite is a ceramic material, derived from zinc and manganese compounds. Transformers rely on them for insulating and resisting high currents.

    What are the Benefits of using them?

    Transformers with Ferrite Cores provide a range of advantages suited to a variety of electrical applications. They offer the following benefits:

    High Magnetic Permeability

    High-frequency transformers utilize ferrite cores because of their magnetic permeability.

    Low Electrical Conductivity

    Eddy current losses are prevented by the low electrical conductivity along with the high permeability of the ferrite cores. This is why, at higher frequencies, the cores perform exceptionally well.

    Higher Coercivity

    Hard ferrite cores are more coercive than soft ferrite cores. Furthermore, they ensure negligible hysteresis losses when changing their magnetic direction.

    In addition to the benefits listed above, these cores provide High Q values, moderate DC sensitivity, Low hysteresis factor, as well as Low signal distortion.

    238 Products showing for Transformer Cores

    EPCOS
    PM 50/39
    Power Transformer
    -
    250nH
    N27
    -
    50mm
    39mm
    -
    -
    EPCOS
    RM 14
    -
    42.2 x 34.8 x 30.2mm
    6000nH
    N87
    30.2mm
    42.2mm
    34.8mm
    -
    -
    EPCOS
    ETD 44
    -
    43.8 x 22.5 x 15.2mm
    3300nH
    N27
    15.2mm
    43.8mm
    22.5mm
    -
    -
    EPCOS
    ETD 44
    -
    43.8 x 22.5 x 15.2mm
    3300nH
    N27
    15.2mm
    43.8mm
    22.5mm
    -
    -
    EPCOS
    ETD 34
    -
    34 x 17.5 x 11.1mm
    135nH
    N87
    11.1mm
    34mm
    17.5mm
    -
    -
    EPCOS
    ETD 34
    -
    34 x 17.5 x 11.1mm
    135nH
    N87
    11.1mm
    34mm
    17.5mm
    -
    -
    EPCOS
    ETD 44
    -
    43.8 x 22.5 x 15.2mm
    3300nH
    N27
    15.2mm
    43.8mm
    22.5mm
    -
    -
    EPCOS
    RM 14
    -
    42.2 x 34.8 x 30.2mm
    160nH
    N41
    30.2mm
    42.2mm
    34.8mm
    -
    -
    EPCOS
    EFD 15/8/5
    DC/DC Converter, Flat Transformers, Power Transformers
    15 x 4.85 x 7.5mm
    780nH
    N87
    7.5mm
    15mm
    4.85mm
    -
    -
    EPCOS
    EFD 15/8/5
    DC/DC Converter, Flat Transformers, Power Transformers
    15 x 4.85 x 7.5mm
    100nH
    N87
    7.5mm
    15mm
    4.85mm
    -
    -
    EPCOS
    E 16/8/5
    Common-Mode Chokes, Power Transformers
    16 x 4.7 x 8.2mm
    1000nH
    N87
    8.2mm
    16mm
    4.7mm
    -
    -
    EPCOS
    RM 12
    -
    37.6 x 29.8 x 24.6mm
    250nH
    N41
    24.6mm
    37.6mm
    29.8mm
    -
    -
    EPCOS
    EFD 15/8/5
    DC/DC Converter, Flat Transformers, Power Transformers
    15 x 4.85 x 7.5mm
    780nH
    N87
    7.5mm
    15mm
    4.85mm
    -
    -
    EPCOS
    RM 12
    -
    37.6 x 29.8 x 24.6mm
    1000nH
    N41
    24.6mm
    37.6mm
    29.8mm
    -
    -
    EPCOS
    ETD 34
    -
    34 x 17.5 x 11.1mm
    135nH
    N87
    11.1mm
    34mm
    17.5mm
    -
    -
    EPCOS
    E 42
    -
    42 x 21.2 x 20mm
    5200nH
    N87
    20mm
    42mm
    21.2mm
    -
    -
    EPCOS
    ER 9.5/5
    Power Transformers
    9.5 x 5 x 5mm
    800nH
    N87
    5mm
    9.5mm
    5mm
    -
    -
    EPCOS
    PQ 50/50
    Power Transformers
    50 x 32 x 25mm
    6500nH
    N87
    25mm
    50mm
    32mm
    -
    -
    EPCOS
    ETD 59
    SMPS Transformers
    59.8 x 31.2 x 22.1mm
    5300nH
    N87
    22.1mm
    59.8mm
    31.2mm
    -
    CRL
    EPCOS
    PQ 50/50
    Power Transformers
    50 x 32 x 25mm
    6500nH
    N87
    25mm
    50mm
    32mm
    -
    -
    Results per page