PR Electronics 5300 Temperature Transmitter Linear Resistance, Potentiometer, RTD, Thermocouple, Voltage Input, 9
- RS Stock No.:
- 827-5435
- Mfr. Part No.:
- 5350A
- Manufacturer:
- PR Electronics
Discontinued product
- RS Stock No.:
- 827-5435
- Mfr. Part No.:
- 5350A
- Manufacturer:
- PR Electronics
Legislation and Compliance
- COO (Country of Origin):
- DK
Product Details
5300 Series - Profibus PA / Foundation Fieldbus Transmitter
PR Electronics 5350 series single input temperature transmitter offers unrivalled performance In applications making heavy demands on accuracy to convert a wide array of input types to a PROFIBUS PA and FOUNDATION Fieldbus communication signal. The 5350 series transmitters are quickly and easily programmable to the specific application. Configuration via a standard PC and user-friendly software, PReset, available as a free download. Parameters for input, output, sensor error detection and process calibration can be configured via PReset within a few minutes.
Features and Benefits
• For DIN form B sensor head mounting
• Sensor drift detection maintains measuring point reliability
• Flexible input capability, with choice of output modes
• Superior accuracy ensures true, reliable measurements
• Fast response time easily supports safety and cost-critical applications
• High immunity to conducted noise: tested against 10 Vrms in the range 15 Hz–100 MHz
• Continuous check of vital stored data for safety reasons
• Runtime meters provide a valuable history of the process temperature and the ambient temperature around the transmitter
• Very low temperature coefficient ensuring maximum accuracy across changing ambient conditions
• Sensor drift detection maintains measuring point reliability
• Flexible input capability, with choice of output modes
• Superior accuracy ensures true, reliable measurements
• Fast response time easily supports safety and cost-critical applications
• High immunity to conducted noise: tested against 10 Vrms in the range 15 Hz–100 MHz
• Continuous check of vital stored data for safety reasons
• Runtime meters provide a valuable history of the process temperature and the ambient temperature around the transmitter
• Very low temperature coefficient ensuring maximum accuracy across changing ambient conditions
Sensor Inputs
The PR 5350 programmable transmitter provides unrivalled input versatility. Virtually any thermocouple or 2, 3 & 4 RTD plus linear resistance up to 10 kΩ and bipolar mV signals. Input sensor redundancy function maintains process availability and safety in the event of primary sensor failure.
Specifications
Attribute | Value |
---|---|
Input Type | Linear Resistance, Potentiometer, RTD, Thermocouple, Voltage |
Supply Voltage | 9 → 32 V dc |
Diameter | 44 mm |
Minimum Temperature Input | -200°C |
Maximum Temperature Input | 850°C |
Minimum Operating Temperature | -40°C |
Maximum Operating Temperature | +85°C |
Series | 5300 |
Depth | 20.2mm |