Schneider Electric Dual-Channel Emergency Stop, Safety Switch/Interlock Safety Relay, 24V dc, 3 Safety Contacts
- RS Stock No.:
- 125-1098
- Mfr. Part No.:
- XPSMP11123P
- Manufacturer:
- Schneider Electric
Temporarily out of stock - back order for despatch 17/06/2024, delivery within 10 working days from desptach date
Added
Price Each
PHP51,059.37
(exc. VAT)
PHP57,186.49
(inc. VAT)
Units | Per Unit |
1 + | PHP51,059.37 |
- RS Stock No.:
- 125-1098
- Mfr. Part No.:
- XPSMP11123P
- Manufacturer:
- Schneider Electric
Legislation and Compliance
RoHS Status: Not Applicable
Product Details
XPS Safety Contactor
Professional range of Schneider Electric safety contactor with pre-defined functions from the Preventa range. The controllers incorporate 2 independent functions. All models are highly reliable and excellent quality.
2 independent functions
Din Rail
IP20 rated terminals
IP40 rated enclosure
Din Rail
IP20 rated terminals
IP40 rated enclosure
Schneider Electric Preventa Safety Contact Controller XPSMP11123P.
The Schneider Electric safety contact XPS MP is a professional range of contactor with pre-defined functions from the Preventa range with 24VDC. The controllers incorporate two independent functions.
XPSMP11123P Features and Benefits.
- Preventa Safety controller with pre-defined function.
- 2 Independent functions applications.
- Category 4 maximum conforming to EN/IEC 60954-1.
- Captive screw clamp terminals.
- 24 V dc rated voltage.
- Power consumption 5 W maximum.
- Internal, Electronic protection.
- 3 NO relays per function (6 NO total), volt-free.
- 3 Solid state outputs.
- Breaking 180 VA holding AC-15 C300 relay output, 1800 VA inrush AC-15 C300 relay output.
- 12 LEDs.
- 35 mm symmetrical DIN rail mounting.
- IP20 (terminals).
- IP40 (enclosure).
Applications.
- Industrial automation
- Pressure sensitive mats
- Safety gates
- Two-hand controls
Certifications.
- UL, BIA, CSA.
Start Types.
- Automatic or unmonitored (configuration 1), Automatic or unmonitored (configuration 10), Automatic or unmonitored (configuration 11), Automatic or unmonitored (configuration 14), Automatic or unmonitored (configuration 3), Automatic or unmonitored (configuration 5), Automatic or unmonitored (configuration 7), Monitored (configuration 12), Monitored (configuration 13), Monitored (configuration 15), Monitored (configuration 2), Monitored (configuration 4), Monitored (configuration 6), Monitored (configuration 8), Monitored (configuration 9).
Standards.
- DIN V VDE 801 + A1, EN/IEC 60204-1, EN/IEC 60947-1 + A11, EN/IEC 60947-5-1.
Safety Level.
- Can reach PL e/category 4 conforming to EN/ISO 13849-1, Can reach SIL 3 conforming to EN/IEC 62061.
Specifications
Attribute | Value |
---|---|
Supply Voltage | 24V dc |
Number of Channels | 2 |
Safety Contacts | 3 |
Function | Emergency Stop, Safety Switch/Interlock |
Auxiliary Contacts | 3 |
Reset Method | Manual |
Range | Preventa |
Safety Category ISO 13849-1 | 4 |
PL ISO 13849-1 | e |
Terminal Type | Screw |
Configurable | Yes |
Series | XPS MP |
Width | 99mm |
Depth | 114mm |
Better World Verification | Green Premium |
Better World Product | Yes |
Length | 45mm |
Performance Level | e |