Omron Dual-Channel Emergency Stop Safety Relay, 24V ac/dc, 2 Safety Contacts
- RS Stock No.:
- 549-570
- Mfr. Part No.:
- G9SB200DACDC24
- Manufacturer:
- Omron
View all Safety Relays
12 In Global stock for delivery NCR Plus within 10 working day(s), rest of PH within 14 working days
Price Each
PHP14,157.37
(exc. VAT)
PHP15,856.25
(inc. VAT)
units | Per Unit |
1 - 5 | PHP14,157.37 |
6 + | PHP13,961.33 |
- RS Stock No.:
- 549-570
- Mfr. Part No.:
- G9SB200DACDC24
- Manufacturer:
- Omron
- COO (Country of Origin):
- CN
Technical data sheets
Legislation and Compliance
- COO (Country of Origin):
- CN
Product Details
G9SB, Safety Relays, Ultra Slim
The Omron G9SB series is an ultra slim safety relay available in either a 17.5mm or 22.5mm housing. The 17.5mm units have 2 or 3 safety contacts and the 22.5mm units have 3 safety contacts and an auxiliary contact.
1 and 2 input channel units
Manual and automatic reset units
Certification up to category 4 according to EN954-1 (depending on the application)
Can also be used with safety sensors F3SN, F3SH, F3S-B, F3STGR, F3SL, F3S-J
Conforms to EN standards (TUV approval)
Manual and automatic reset units
Certification up to category 4 according to EN954-1 (depending on the application)
Can also be used with safety sensors F3SN, F3SH, F3S-B, F3STGR, F3SL, F3S-J
Conforms to EN standards (TUV approval)
Note
When ordering take note of the safety reset mode that is required: Models G9SB**A and G9SB ** B = Auto Reset operation; Models G9SB ** D = Manual Reset operation
Approvals
EN954-1, EN60204-1, UL508, CSA C22.2 No. 14
G9SB Ultra Slim Safety Relays.
Ultra slim relay module.
Models with a width of 17.5 mm are available with 2 or 3 poles (safety contacts).
Models with a width of 22.5 mm with 3 poles (safety contacts).
1 and 2 input channels.
Manual and automatic reset.
Can be DIN rail mounted.
Relays with inverse inputs are used when inputting signals from 2 mechanical switches.
Relays with positive commons are used when inputting signals from a safety sensor or one mechanical switch.
Conform to EN standards (TUV approval).
G9SB-3010 is applied to safety category 3 of EN 954-1 if double breaking is used.
Models with a width of 17.5 mm are available with 2 or 3 poles (safety contacts).
Models with a width of 22.5 mm with 3 poles (safety contacts).
1 and 2 input channels.
Manual and automatic reset.
Can be DIN rail mounted.
Relays with inverse inputs are used when inputting signals from 2 mechanical switches.
Relays with positive commons are used when inputting signals from a safety sensor or one mechanical switch.
Conform to EN standards (TUV approval).
G9SB-3010 is applied to safety category 3 of EN 954-1 if double breaking is used.
Applicable to Safety Sensors.
Model F3S-B
Model F3SH
Model F3S-J
Model F3SL
Model F3SN
Model F3S-TGR
Model F3SH
Model F3S-J
Model F3SL
Model F3SN
Model F3S-TGR
Model F3S-TGR Safety Sensors covers a range of articles available within Non-Contact Safety Switches, Light Curtains, Light Beams and Machine Guarding Accessories.
G9SB-200-D ACDC24 Slim Safety Relay.
Main contact DPST-NO (normally open).
No Auxiliary contact
1 Channel or 2 Channels possible.
Manual reset
Input type +Common
Rated voltage 24 V ac/dc.
Operating voltage range 85% to 110% of the rated power supply voltage.
Power consumption 1.6 VA/1.4 W max.
Input current 25 mA max.
Resistive load
Rated load 250 V ac, 5 A. 30 V dc, 5 A.
Rated carry current 5 A.
No Auxiliary contact
1 Channel or 2 Channels possible.
Manual reset
Input type +Common
Rated voltage 24 V ac/dc.
Operating voltage range 85% to 110% of the rated power supply voltage.
Power consumption 1.6 VA/1.4 W max.
Input current 25 mA max.
Resistive load
Rated load 250 V ac, 5 A. 30 V dc, 5 A.
Rated carry current 5 A.
Features and Benefits.
Contact resistance 100 mΩ
Insulation resistance 100 MΩ mon (at 500 V dc)
Vibration resistance 10 to 55 to 10 Hz, 0.375 mm single amplitude (0.75 mm double amplitude)
Shock resistance destruction 300 m/s².
Shock resistance malfunction 100 m/s²
Failure rate (P Level) (reference value) 5 V dc, 1 mA
Always turn OFF the G9SB before connecting an expansion unit.
If mounting multiple units next to each other the rated current will be 3 A. (do not apply any higher currents)
Stranded wire 0.2 to 2.5 mm²
Solid Wire 0.2 to 2.5 mm²
Screw torque of 0.5 to 0.6 Nm. (incorrect screw tightening can result in a malfunction or generate heat).
Positive thermistor built onto the circuits detecting short breakdowns.
Weight 115 g
Insulation resistance 100 MΩ mon (at 500 V dc)
Vibration resistance 10 to 55 to 10 Hz, 0.375 mm single amplitude (0.75 mm double amplitude)
Shock resistance destruction 300 m/s².
Shock resistance malfunction 100 m/s²
Failure rate (P Level) (reference value) 5 V dc, 1 mA
Always turn OFF the G9SB before connecting an expansion unit.
If mounting multiple units next to each other the rated current will be 3 A. (do not apply any higher currents)
Stranded wire 0.2 to 2.5 mm²
Solid Wire 0.2 to 2.5 mm²
Screw torque of 0.5 to 0.6 Nm. (incorrect screw tightening can result in a malfunction or generate heat).
Positive thermistor built onto the circuits detecting short breakdowns.
Weight 115 g
Applications Include.
Light curtain.
Light guard.
Light guard.
Specifications
Attribute | Value |
Supply Voltage | 24V ac/dc |
Number of Channels | 2 |
Safety Contacts | 2 |
Function | Emergency Stop |
Reset Method | Manual |
Safety Category ISO 13849-1 | 4 |
Width | 18mm |
Series | G9SB |
Depth | 112mm |
Length | 100mm |