SICK FLEXIS Series Input/Output Module, 2 Inputs
- RS Stock No.:
- 213-3782
- Mfr. Part No.:
- FX3-ANA020002
- Manufacturer:
- SICK
Subtotal (1 unit)*
PHP39,187.73
(exc. VAT)
PHP43,890.26
(inc. VAT)
Add 1 unit to get free delivery
Temporarily out of stock
- Shipping from April 14, 2026
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per Unit |
|---|---|
| 1 + | PHP39,187.73 |
*price indicative
- RS Stock No.:
- 213-3782
- Mfr. Part No.:
- FX3-ANA020002
- Manufacturer:
- SICK
Specifications
Technical data sheets
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | SICK | |
| Product Type | Input/Output Module | |
| Series | FLEXIS | |
| Mount Type | DIN Rail | |
| Sub Type | Analogue Input Module | |
| For Use With | Flexi Soft System | |
| Number of Inputs | 2 | |
| Power Rating | 2W | |
| Terminal Type | Spring Terminal | |
| Hazardous Area Certification | No | |
| Standards/Approvals | PL e (EN ISO 13849), SILCL3 (EN 62061), TM (mission time) 20 years (EN ISO 13849-1), PFHD (mean probability of a dangerous failure per hour) 0.166 x 10-9, SIL3 (IEC 61508), Category 4 (EN ISO 13849) | |
| Select all | ||
|---|---|---|
Brand SICK | ||
Product Type Input/Output Module | ||
Series FLEXIS | ||
Mount Type DIN Rail | ||
Sub Type Analogue Input Module | ||
For Use With Flexi Soft System | ||
Number of Inputs 2 | ||
Power Rating 2W | ||
Terminal Type Spring Terminal | ||
Hazardous Area Certification No | ||
Standards/Approvals PL e (EN ISO 13849), SILCL3 (EN 62061), TM (mission time) 20 years (EN ISO 13849-1), PFHD (mean probability of a dangerous failure per hour) 0.166 x 10-9, SIL3 (IEC 61508), Category 4 (EN ISO 13849) | ||
- COO (Country of Origin):
- HU
Overview
At a glance
Your Benefit
The Flexi Soft safety controller can be programmed via software. Thanks to the modular hardware platform, Flexi Soft provides a tailored and efficient solution for a whole host of safety applications. A wide range of modules are available: main modules, gateways, digital and analog input/output modules, Motion Control modules, as well as relay modules. The license-free Flexi Soft Designer configuration software enables intuitive programming, rapid commissioning, and continuous diagnostics down to the automation level. Functions to enable safe controller networking, safe series connection, or safe drive monitoring reduce costs and boost productivity. A whole host of additional functions means that Flexi Soft is able to bridge the gap to system solutions from SICK.
Applications
Modular adaptation to the particular requirement means optimum scalability and therefore cost savings
Intuitive configuration software featuring comprehensive functions for straightforward engineering
Rapid verification of the safety application: The configuration software provides documentation and a wiring diagram
The main module's diagnostics interfaces and the configuration storage facility in the system plug enable rapid commissioning, component replacement, and troubleshooting, resulting in minimum downtimesSafety controller with modular hardware platform
Configuration saved in the system plug
Safe controller networking with Flexi Line
Safe series connection with Flexi Loop
Safe drive monitoring
Safe analog value monitoring
Flexi Soft Designer license-free configuration software
Related links
- SICK FLEXIS Series Input/Output Module, Via FLEXBUS+
- Eaton EU2E Series Input/Output Module, 2 Inputs
- Phoenix Contact PSR Series Input/Output Module 24 V
- Phoenix Contact PSR Series Input/Output Module 1 Outputs, 24 V
- Phoenix Contact PSR Series Input/Output Module 5 Outputs 5NO
- Schneider Electric TPRAN Series Input/Output Module 1 Outputs, 24 V dc
- Siemens 3RK1405 Series Input/Output Module 2 Outputs, 24 V
- Eaton EU2E Series Input/Output Module 28.8 V dc