SICK FLEXIL Series Input/Output Module, 2 Inputs, 5 Outputs, 24 V dc

Subtotal (1 unit)*

PHP8,799.26

(exc. VAT)

PHP9,855.17

(inc. VAT)

Add to Basket
Select or type quantity
Temporarily out of stock
  • Shipping from April 13, 2026
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units
Per Unit
1 +PHP8,799.26

*price indicative

RS Stock No.:
213-3768
Mfr. Part No.:
FLA-MSTR00002
Manufacturer:
SICK
Find similar products by selecting one or more attributes.
Select all

Brand

SICK

Series

FLEXIL

Product Type

Input/Output Module

Sub Type

Module for Connection Flexi Classic to IO-Link

For Use With

Flexi Soft System

Supply Voltage

24 V dc

Number of Inputs

2

Number of Outputs

5

Standards/Approvals

UL, CE

Hazardous Area Certification

No

COO (Country of Origin):
HU

Overview


At a glance


Your Benefit


Flexi Loop can connect up to 32 safety sensors in series in compliance with the highest performance level PL e. Safety switches and safety sensors with OSSD outputs can be used together, regardless of manufacturer. Detailed diagnostic information is also available for each sensor or switch. Integrated switching signals allow for the use of interlocks, switches, and lamps. All sensors are supplied with voltage directly from the Flexi Loop. Unshielded standard cables are used with M12 male connectors. Ultimately, Flexi Loop can be relied upon for maximum safety. Connecting sensors in series reduces the amount of wiring and the number of safety inputs in the control cabinet. It also provides a comprehensive diagnostic check of all doors, emergency stop pushbuttons, and sensors. In conjunction with Flexi Soft and Flexi Classic, the entire safety application is able to cost-effectively meet customer needs.

Applications


Connecting both safety switches and safety sensors with OSSD outputs in series minimizes the amount of wiring and the number of inputs at the safety controller, thus reducing costs.

Simple calculation of the performance level saves time since the Flexi Loop node monitors each sensor individually

Quick and easy configuration saves time

Ability to be used over long distances increases application flexibility

Detailed diagnostic information – who switched and why? minimizes system downtime

Seamless system integration and communication with other SICK safety controllers

Detailed status information on Flexi Loop components, diagnostic accessories, and safety controller enable quick and easy field diagnosticsSeries connection of 32 sensors with up to 100 m per segment in compliance with performance level PL e

Compatible with sensors from all manufacturers

Detailed diagnostic information

Integrated standard inputs and outputs

Voltage supply for sensors is included