Specifications
Technical data sheets
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | Theben / Timeguard | |
| Number of Gangs | 1 | |
| RCD Type | Active | |
| Series Name | Tripfast | |
| Colour | White | |
| Switched | Yes | |
| Trip Speed | 40ms | |
| Faceplate Depth | 20mm | |
| Current Rating | 13A | |
| Voltage Rating | 230 V ac | |
| Minimum Box Depth | 25mm | |
| Number of Poles | 2 | |
| Series | Tripfast | |
| Height | 85mm | |
| Trip Current | 30mA | |
| Faceplate Mounting Type | Screwed | |
| Switch Style | Rocker | |
| Fixing Standard | BS | |
| Colour Family | White | |
| Earth Terminal | Yes | |
| Width | 85mm | |
| Select all | ||
|---|---|---|
Brand Theben / Timeguard | ||
Number of Gangs 1 | ||
RCD Type Active | ||
Series Name Tripfast | ||
Colour White | ||
Switched Yes | ||
Trip Speed 40ms | ||
Faceplate Depth 20mm | ||
Current Rating 13A | ||
Voltage Rating 230 V ac | ||
Minimum Box Depth 25mm | ||
Number of Poles 2 | ||
Series Tripfast | ||
Height 85mm | ||
Trip Current 30mA | ||
Faceplate Mounting Type Screwed | ||
Switch Style Rocker | ||
Fixing Standard BS | ||
Colour Family White | ||
Earth Terminal Yes | ||
Width 85mm | ||
RoHS Status: Not Applicable
- COO (Country of Origin):
- CN
White RCD Sockets
Single & double gang socket versions
Single gang available with active circuitry
Double gang available with active or passive circuitry
Single gang available with active circuitry
Double gang available with active or passive circuitry
Standards
BS1363; BS7288
Timeguard RCD's
Current Rating 13A
Voltage Rating 220 - 240Vac
Trip Current 30mA
Trip Time 40ms
Conforms to BS1363 and BS7288
Voltage Rating 220 - 240Vac
Trip Current 30mA
Trip Time 40ms
Conforms to BS1363 and BS7288
Designed to provide protection against the risk of electrocution and fire hazards.
Passive circuitry - power is restored immediately after a power failure.
Active circuitry - power is only restored after device has been manually reset, thus protecting against equipment suddenly re-energising.
Passive circuitry - power is restored immediately after a power failure.
Active circuitry - power is only restored after device has been manually reset, thus protecting against equipment suddenly re-energising.