Siemens, Sentron MCCB Molded Case Circuit Breaker 100 A, Breaking Capacity 25 kA, Fixed Mount
- RS Stock No.:
- 874-4152
- Mfr. Part No.:
- 3VA1110-3EE36-0AA0
- Manufacturer:
- Siemens
Stock information currently inaccessible
- RS Stock No.:
- 874-4152
- Mfr. Part No.:
- 3VA1110-3EE36-0AA0
- Manufacturer:
- Siemens
Specifications
Technical data sheets
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | Siemens | |
| Range | Sentron | |
| Series | 3VA | |
| Number of Poles | 3 | |
| Current Rating | 100A | |
| Breaking Capacity at Maximum Voltage Rating | 25 kA | |
| Rated AC Voltage | 690V | |
| Rated DC Voltage | 500V | |
| Length | 76.2mm | |
| Width | 130mm | |
| Depth | 88mm | |
| Reset Actuator Type | Toggle Switch | |
| Tripping Mechanism | Thermal-Magnetic | |
| Break Time | Instantaneous | |
| Circuit Breaker Type | MCCB | |
| Mounting Hole Diameter | 4.2mm | |
| Select all | ||
|---|---|---|
Brand Siemens | ||
Range Sentron | ||
Series 3VA | ||
Number of Poles 3 | ||
Current Rating 100A | ||
Breaking Capacity at Maximum Voltage Rating 25 kA | ||
Rated AC Voltage 690V | ||
Rated DC Voltage 500V | ||
Length 76.2mm | ||
Width 130mm | ||
Depth 88mm | ||
Reset Actuator Type Toggle Switch | ||
Tripping Mechanism Thermal-Magnetic | ||
Break Time Instantaneous | ||
Circuit Breaker Type MCCB | ||
Mounting Hole Diameter 4.2mm | ||
- COO (Country of Origin):
- CZ
Siemens 3VA1 MCCBs
The new 3VA1 molded case circuit breakers reliably perform all the tasks associated with line protection.
The devices of the 3VA1 series fulfill all standard tasks in line protection, thanks to their particularly compact design, 3VA1 MCCBs are the perfect choice for applications in distribution boards and machine engineering.
They are easily mounted as fixed or plug-in versions.
The basic trigger for overload or short-circuit protection is a thermal-magnetic, electronic trip unit (TMTU) and is suitable for use in three-phase, AC, and DC networks.
The devices of the 3VA1 series fulfill all standard tasks in line protection, thanks to their particularly compact design, 3VA1 MCCBs are the perfect choice for applications in distribution boards and machine engineering.
They are easily mounted as fixed or plug-in versions.
The basic trigger for overload or short-circuit protection is a thermal-magnetic, electronic trip unit (TMTU) and is suitable for use in three-phase, AC, and DC networks.
Compact design
Thermal-magnetic trip units
AC/DC applications
No derating up to +50 °C
Thermal-magnetic trip units
AC/DC applications
No derating up to +50 °C
Siemens 3VA MCCBs and accessories
Related links
- Siemens Breaking Capacity 36 kA, Fixed Mount
- Siemens 3VA1 Molded Case Circuit Breaker 3-Pole 100 A Fixed
- Siemens SENTRON Molded Case Circuit Breaker 3-Pole 40 A Fixed
- Siemens SENTRON Molded Case Circuit Breaker 3-Pole 50 A Fixed
- Siemens SENTRON Molded Case Circuit Breaker 3-Pole 20 A Fixed
- Siemens SENTRON Molded Case Circuit Breaker 3-Pole 32 A Fixed
- Siemens SENTRON Molded Case Circuit Breaker 3-Pole 80 A Fixed
- Siemens SENTRON Molded Case Circuit Breaker 3-Pole 16 A Fixed