Better World

Schneider Electric LC1D Contactor, 24 V ac Coil, 4-Pole, 32 A, 1.56 W 24 V, 4 NO, 690V

Subtotal (1 unit)*

PHP7,048.64

(exc. VAT)

PHP7,894.48

(inc. VAT)

Add to Basket
Select or type quantity
In Stock
  • 17 unit(s) ready to ship from another location
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units
Per Unit
1 +PHP7,048.64

*price indicative

Better World

Our Better World range features products that make it easy for you to make a greener product choice you can trust. Click here to find out more.

RS Stock No.:
454-7828
Mfr. Part No.:
LC1DT32B7
Manufacturer:
Schneider Electric
Find similar products by selecting one or more attributes.
Select all

Brand

Schneider Electric

Product Type

Contactor

Coil Voltage

24 V ac

Number of Poles

4

Contact Voltage

690V

Contact Current

32A

Series

LC1D

Power Rating

1.56W

Mount Type

DIN Rail

Function

Motor Control

Normal State Configuration

4 NO

Number of Auxiliary Contacts

2

Auxiliary Contact Configuration

1 NO/1 NC

Terminal Type

Screw

Control Circuit Voltage Uc

24 V

Contactor Application

Resistive Load

Operational Current Ie

32A

Minimum Operating Temperature

-5°C

Maximum Operating Temperature

60°C

Length

91mm

Width

45 mm

Depth

97mm

Standards/Approvals

CCC, UL, RoHS, IEC, EAC, CSA

Better World Product

Yes

Pole and Throw Configuration

4

RoHS Status: Exempt

COO (Country of Origin):
ID

Schneider Electric LC1DT32B7


TeSys Deca contactor, 4 poles (4NO), for non-inductive load applications up to 32A/440V AC-1. They can be used to create motor starters for almost any type of application. It provides a 24V 50/60Hz AC coil, 1NO+1NC built-in auxiliary contacts (NC mirror certified), connection by screw clamp terminals. For operating rates until 3600 cycles/hour and environments until 60°C, it procures high reliability and durability. Compact (45mm width), DIN-rail mounting or screw fixing. Power contacts have a 32A resistive load rating. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh). Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 3.58 inches tall, 1.77 inches wide and 3.90 inches deep. It weighs 0.94 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.

Features & Benefits


• IP20 rating means it's touch-proof and protected against tools and wires larger than 12mm

• Screw clamp terminals for secure, vibration-proof wiring

• Compact dimensions of 91 (H) x 45 (W) x 99mm (D) for installation in crowded setups

• Wide operating temperature range between -40°C and +60°C for use in harsh environments

Applications


• Motor starters

• Industrial automation

• Automotive manufacturing

How many times can this contactor switch in an hour?


This unit achieves up to 3600 cycles per hour, so it's sure to keep up with intense switching demands.

Schneider Electric LC1D TeSys D Contactors


TeSys D Contactors from Schneider Electric combine long mechanical and electrical life to offer a high reliable contactor. The range has been designed for integration in control systems and can be used to create motor starters for any type of application. The TeSys D contactors offer quick simple setup while maintaining compliance with international standards.

Features and Benefits


• Built-in auxiliary contacts for added switching capability

• Screw connections: IP20 finger-safe terminals with both North American and International terminal markings

• Can be panel mounted with screws or DIN Rail mounted

• Bidirectional peak limiting diode suppressor to protect the coil

• Easily installed accessories

• Flexible control circuit to suit a wide range of applications

What does the utilisation category AC1 and AC3 mean for the TeSys contactors?


Contactor utilisation categories define the current making and breaking values, based on the type of load to be controlled and the operating cycle conditions.

  • AC-1: This applies to all AC devices with a power factor of at least 0.95. Example of use: resistive load, heating, distribution.

  • AC-3: This applies to squirrel cage motors where breaking occurs while the motor is running. Example of use: all squirrel cage motors, lifts, escalators, conveyors, bucket elevators, compressors, pumps, mixers, air conditioning units.

  • What accessories are available?


    • Auxiliary contact blocks with serrated wiping action

    • Front mount dust tight auxiliary contact blocks

    • Pneumatic time delay blocks

    • Transient voltage surge suppressors

    • Interface modules and electronic timers

    • Mechanical latching blocks

    Is the TeSys D range a double break pole type contactor?


    Yes the Tesys D range uses linear translation movement that provides double breaking of the poles.