Cooper Bussmann, 80A, A4, British Standard Fuse, gG, 550V ac

Technical data sheets
Legislation and Compliance
RoHS Status: Not Applicable
Product Details

Cooper Bussman Bolted Tag Fuse - British Standard

Cooper Bussman's bolted tag fuse is essentially a fuse that is fitted with brackets, these brackets allow the fuse to be bolted onto a fuse holder. Predominantly, this type of fuse is used within installations as a "weak link". They are designed to break when a fault occurs, such as an overcurrent or short circuit - they are a safety and damage measure. Cooper Bussman's fuses are commonly found within a multitude of industrial applications, electrical equipment and wiring systems.

Features & Benefits

• The low-temperature rise enables the fuse to be suitable for high-density mounting applications
• Fuse links, specifically designed for the protection of applications
• Conforms to industry standards
• Low voltage fuse
• Suitable for three-phase applications
• Suitable for type 2 co-ordinated applications as defined in IEC 947-4
• Low power loss, typically 20% lower than the requirements of BS88

//media.rs-online.com/t_line/L413793-01.gif
Specifications
Attribute Value
Current Rating 80 A
Fuse Size A4
Voltage Rating 550 V ac
Fuse Standard BS 88, IEC 269
Fixing Centres 94mm
Application Category GG
Tag Width 14.3mm
High Rupture Capacity Yes
Overall Length 110mm
Body Diameter 21mm
Body Height 58.5mm
268 In Global stock for delivery within 4 - 8 working days
Price Each
PHP 2,830.80
(exc. VAT)
PHP 3,170.50
(inc. VAT)
units
Per Unit
1 - 9
PHP2,830.80
10 - 24
PHP2,648.16
25 - 49
PHP2,602.48
50 - 99
PHP2,556.84
100 +
PHP2,511.19
Related Products
Semiconductor fuse links have a precise pre-determined performance ...
Description:
Semiconductor fuse links have a precise pre-determined performance which ensures a low arc voltage and minimum let through current. Semiconductor fuses are suited to application in the field of traction, distribution of power, motor drives and in process industries. Melt ...
As the fuse allows for the starting surge ...
Description:
As the fuse allows for the starting surge of a motor its full load current must not exceed the lesser of the dual current rating. e.g. 20 M25 must not have a continuous load of greater than 20A. Breaking capacity ...
Eaton’s Bussmann® series fuse links, size F2, are ...
Description:
Eaton’s Bussmann® series fuse links, size F2, are specifically designed for the protection of general industrial applications e.g. power distribution and cable protection. Good peak let-through current limitation1:1:6 Selective coordination ratio between “minor” and “major” fuse.
Breaking capacity 80kA at 415Vac and 40kA at ...
Description:
Breaking capacity 80kA at 415Vac and 40kA at 250Vdc (bolted connection types) (E1 type 16·5kA at 240Vac)Rated at 415Vac/250Vdc (bolted connection types) (E1 type 240Vac)Electricity Supply Authorities, Lloyd’s Register of Shipping Approvals and ASTA 20 certified.