Trace Heating Cable

What is Trace Heating Cable?
Trace heating cables are electric heating elements designed to provide focused and controllable heat used to prevent pipes, outdoor taps and gutters from freezing, or to maintain a desired temperature on pipes to keep liquids moving. Trace heating cables are constructed from thermoplastic layers containing a self-regulating heating element and two adjacent bus wires.
How does Trace heating work?
Trace heating cables are created by placing a semi conductive self-regulating heating matrix around two bus wires, one live and one neutral. When power is connected to these bus wires the matrix receives either voltage, causing it to heat up.
How are they used?
Trace heating is easy to install on pipework, tanks or vessels using cable ties, aluminium or glass fibre tape or a suitable adhesive prior to covering with insulation. The cable can be cut to any length allowing them to be manipulated to suit any application. All trace heating applications should be temperature controlled using a suitable thermostat.

...
Read more Read less

Filters

Viewing 1 - 20 of 60 products
Results per page
Description Price Cable Type Output per Metre Self Regulating Voltage Rating Minimum Operating Temperature Maximum Operating Temperature Operating Temperature Range Length Sheath Material Sheath Colour Hazardous Area Certification Standards Met
RS Stock No. 703-3224
BrandRS PRO
PHP73,485.12
1 Reel of 100 Metre(s)
Reel(s)
Self Regulating 40W Yes 240 V - +80°C Maximum of +80 (Un-Energised) °C 100m Polyolefin - - BS EN 62395
RS Stock No. 703-3212
BrandRS PRO
PHP16,535.00
1 Reel of 20 Metre(s)
Reel(s)
Self Regulating 40W Yes 240 V - +80°C Maximum of +80 (Un-Energised) °C 20m Polyolefin - - BS EN 62395
RS Stock No. 703-3221
BrandRS PRO
PHP39,187.16
1 Reel of 50 Metre(s)
Reel(s)
Self Regulating 40W Yes 240 V - +80°C Maximum of +80 (Un-Energised) °C 50m Polyolefin - - BS EN 62395
RS Stock No. 379-738
BrandRS PRO
PHP3,795.76
1 Reel of 6 Metre(s)
Reel(s)
Constant Wattage, Parallel Circuit 10W - 240 V -70°C +200°C -70 → +200 °C 6m Silicone Rubber - - RoHS Compliant
RS Stock No. 665-7514
BrandRS PRO
PHP21,515.22
1 Reel of 20 Metre(s)
Reel(s)
Constant Wattage 30W No 240 V -60°C +200°C -60 → +200 °C 20m Silicone Rubber - ATEX BS EN 60079-0:2009, BS EN 60079-30-1:2007
RS Stock No. 263-2491
Mfr. Part No.FROSTOP-B-KIT
BrandRaychem
PHP18,559.81
1 Kit
Kit(s)
Frost Protection 18W Yes 230 V - +65°C Maximum of +65 °C 30m - - - -
RS Stock No. 379-722
BrandRS PRO
PHP3,030.81
1 Reel of 3 Metre(s)
Reel(s)
Constant Wattage, Parallel Circuit 10W - 240 V -70°C +200°C -70 → +200 °C 3m Silicone Rubber - - RoHS Compliant
RS Stock No. 379-744
BrandRS PRO
PHP15,981.84
1 Reel of 20 Metre(s)
Reel(s)
Constant Wattage, Parallel Circuit 20W - 240 V -60°C +200°C -60 → +200 °C 20m Silicone Rubber - - BS EN 62395-1:2006, RoHS Compliant
RS Stock No. 256-244
BrandRS PRO
PHP11,608.12
1 Reel of 20 Metre(s)
Reel(s)
Constant Wattage, Parallel Circuit 15W - 240 V -60°C +200°C -60 → +200 °C 20m Silicone Rubber - - BS EN 62395-1:2006, RoHS Compliant
RS Stock No. 665-7438
BrandRS PRO
PHP64,300.27
1 Reel of 100 Metre(s)
Reel(s)
Constant Wattage, Parallel Circuit 40W - 240 V -60°C +200°C -60 → +200 °C 100m Silicone Rubber - - BS EN 62395-1:2006
RS Stock No. 703-3218
BrandRS PRO
PHP71,648.40
1 Reel of 100 Metre(s)
Reel(s)
Self Regulating 30W Yes 240 V - +80°C Maximum of +80 (Un-Energised) °C 100m Polyolefin - - BS EN 62395
RS Stock No. 665-7450
BrandRS PRO
PHP13,227.76
1 Reel of 20 Metre(s)
Reel(s)
Self Regulating 10W Yes 240 V - +80°C Maximum of +80 (Un-Energised) °C 20m Polyolefin - - BS EN 62395
RS Stock No. 703-3206
BrandRS PRO
PHP18,191.35
1 Reel of 20 Metre(s)
Reel(s)
Self Regulating 30W Yes 240 V - +80°C Maximum of +80 (Un-Energised) °C 20m Polyolefin - - BS EN 62395
RS Stock No. 665-7457
BrandRS PRO
PHP67,974.33
1 Reel of 100 Metre(s)
Reel(s)
Self Regulating 10W Yes 240 V - +80°C Maximum of +80 (Un-Energised) °C 100m Polyolefin - - BS EN 62395
RS Stock No. 665-7453
BrandRS PRO
PHP33,987.66
1 Reel of 50 Metre(s)
Reel(s)
Self Regulating 10W Yes 240 V - +80°C Maximum of +80 (Un-Energised) °C 50m Polyolefin - - BS EN 62395
RS Stock No. 703-3215
BrandRS PRO
PHP38,207.18
1 Reel of 50 Metre(s)
Reel(s)
Self Regulating 30W Yes 240 V - +80°C Maximum of +80 (Un-Energised) °C 50m Polyolefin - - BS EN 62395
RS Stock No. 379-312
Mfr. Part No.FS-A-2X
BrandRaychem
PHP23,086.01
1 Kit
Kit(s)
Frost Protection 10W Yes 230 V -20°C +65°C 20 → +65 °C 20m Polyolefin Brown - -
RS Stock No. 379-974
Mfr. Part No.12XTV2-CT-T3
BrandRaychem
PHP55,034.72
1 Reel of 20 Metre(s)
Reel(s)
Process Temperature Maintenance & Frost Protection 40W Yes 230 V - +121°C Maximum of +121 °C - Fluoropolymer Red ATEX -
RS Stock No. 665-7429
BrandRS PRO
PHP35,386.54
1 Reel of 50 Metre(s)
Reel(s)
Constant Wattage, Parallel Circuit 40W - 240 V -60°C +200°C -60 → +200 °C 50m Silicone Rubber - - BS EN 62395-1:2006
RS Stock No. 263-2479
Mfr. Part No.HWAT-M
BrandRaychem
PHP23,990.36
1 Kit
Kit(s)
Hot Water Maintenance 9W Yes 230 V ac - +65°C Maximum of +65 (Continuous Exposure Temperature) °C 20m - Orange - -
Related Products
These solid cables can be used in low-voltage ...
Description:
These solid cables can be used in low-voltage energy or remote control installations in semi-industrial and industrial applications. Typical applications include power supply for lighting, electrical devices, motors, electrical connections, risers, etc.
The RS range of intruder alarm signal cable ...
Description:
The RS range of intruder alarm signal cable is made of the highest quality raw materials. 7 strandsGrade 1 tinned annealed copper conductorsPVC insulatedLead and tin freeWhite PVC sheathEasy to stripFlexible100 and 500m lengths.
The RS range of intruder alarm signal cable ...
Description:
The RS range of intruder alarm signal cable is made of the highest quality raw materials. 7 strandsGrade 1 tinned annealed copper conductorsPVC insulatedLead and tin freeWhite PVC sheathEasy to stripFlexible100 and 500m lengths.
Designed to be cut from reel lengths and ...
Description:
Designed to be cut from reel lengths and site terminated to suit pipework. The heating tape consists of a number of short heating zones, each connected across a pair of continuous bus-wire conductors. Each complete heating zone will give its ...