Schneider Electric | Preventa XPSAF Series | Safety Relays

Simple and effective safety monitoring has never been more crucial in today's highly automated world. Prevention is key to site safety, that's why Schneider Electric offers a Safety Relay in the form of the 'Preventa XPSAF' module that is second to none. Being able to monitor faults with devices along a circuit has the power to stop emergency situations from even occurring.

Features and benefits:

• Single-channel with 3 N/O safety outputs

• Monitoring of a movable guard, with emergency stop monitoring 1 or 2 channel wiring usable.

• Configurable type of start is readily available for the type of activation you wish for your circuit.

• Monitoring of single safety functions, providing an automated solution for use with applications such as emergency push stop buttons or switches.

• Unlimited synchronisation between time inputs.

• Slin in design, with just 22.5mm of width meaning it can fit nicely even in space constraint spaces.

• Accepts cable up to 2.5mm²

• Symmetrical DIN rail support, offering flexible and versatile safety system installation.

• Local signalling in the form of LEDs.

Protection ratings & Safety features (see datasheet for specifics) -

• Impressive line resistance is available, varying between 90 to 100 Ohm (Ω).

• Input protection type is internal, electronic.

• EN1088/ISO 14119, EN 60204-1, EN/IEC 60947-5-1, EN/ISO 13850

• CSA, TUV & UL listed

• IP 40 (enclosure) for protection against small objects up to 1mm such as tools, wires and small wires.

• IP 20 (terminals) for protection against solid objects such as fingers, smaller tools up to 12mm.

• -25 to 60°C temperature range for operation, suitable in varying levels of heat/freezing temperatures.

Applications -

All dangerous machinery requires an automated solution to prevent harm to immediate users and also prevent damage to the machinery. Below are some of the safety applications

• Coded Magnetic Switch (CMS) to prevent tampering by unauthorised users.


• Time delay input if needed allowing you to set up your own time function.

• Light curtains / Two-hand control safety circuits

• Sensing mats and edges

Standards

IEC 204-1; EN 292; EN 418; EN 60204-1; EN 1088

Approvals

BG, UL, CSA

Specifications
Attribute Value
Supply Voltage 24 V ac/dc
Number of Channels 1, 2
Function Safety Switch/Interlock
Safety Contacts 3
Range Preventa
Terminal Type Screw
Length 99mm
Depth 114mm
Width 22.5mm
107 In Global stock for delivery within 4 - 8 working days
Price Each
PHP 19,775.07
(exc. VAT)
PHP 22,148.08
(inc. VAT)
units
Per Unit
1 - 5
PHP19,775.07
6 +
PHP19,575.41
Related Products
2 N/O instantaneous outputs provide stop category 0, ...
Description:
2 N/O instantaneous outputs provide stop category 0, 3 N/O timed contacts provide stop category 1 by allowing controlled deceleration of the motor until a complete stop is achieved4 solid state outputs for PLC signallingMonitored start button featureDelay time: 0 ...
The Omron G9SB series is an ultra slim ...
Description:
The Omron G9SB series is an ultra slim safety relay available in either a 17.5mm or 22.5mm housing. The 17.5mm units have 2 or 3 safety contacts and the 22.5mm units have 3 safety contacts and an auxiliary contact. 1 ...
The Phoenix Contact 2700525 safety relay is designed ...
Description:
The Phoenix Contact 2700525 safety relay is designed for emergency stop (E-Stop), light grids and safety doors up to Cat.4/PL e according to ISO 13849-1, SILCL 3 according to IEC 62061With 3 enabling current path and 1 signalling current path ...
The Phoenix Contact 2702356 safety relay module is ...
Description:
The Phoenix Contact 2702356 safety relay module is designed for the monitoring of 1 and 3 phase AC or DC motors up to Cat.3/PL e according to ISO 13849-1, SILCL 3 according to IEC 62061.With 1 enabling current path and ...