Preventa XPSMCM Ethernet I/P Communication Module, 24 V dc

Technical data sheets
Legislation and Compliance
RoHS Status: Not Applicable
COO (Country of Origin): IT
Product Details

Preventa Non-safe Fieldbus Communication Modules, XPSMCM

The Preventa XPSMCM non-safe fieldbus communication modules are designed for diagnostic connection and data communication to machine field bus or network systems. They have a compact designed, 22.5 x 99 x 114.5 mm, the same size as a typical safety relay.

Features and Benefits

Connected to the safety controller via the expansion bus connector
Mini USB 2.0 connector for configuration
Only one non-safe communication module type can be connected on a safety controller
Removable screw-type terminal blocks for connecting the machine bus or networks channels and/or the power supply
LED status indication
Symmetrical DIN rail locking clip
Green premium product
RoHS compliant

Stock no. 111-3504

Ethernet IP
1x RJ 45 (in/out) connector

Stock no. 111-3508

Universal Serial Bus
Mini USB connector

Stock no. 111-3505

Modbus TCP
1x RJ 45 (in/out) connector

Note

The XPSMCM system is TUV SUD certified to Cat 4, PLe EN/ISO 13849-1 and SILCL 3 IEC/EN 61508 & IEC/EN 60261 standards.

Approvals

CE, cULus, TUV.

Specifications
Attribute Value
Range Preventa
Series XPSMCM
Type Communication Module
For Use With Preventa Modular Safety Controller
Supply Voltage 24 V dc
Field Bus Communication Type Ethernet I/P
Messaging Communication, I/O Messages, Power Supply, Reset
Connection Type RJ45
Display Included Yes
Mounting Style DIN Rail
Dimensions 22.5 x 99 x 114.5 mm
Temporarily out of stock - back order for despatch 02/07/2020, delivery within 5 working days from desptach date
Price Each
PHP 25,446.75
(exc. VAT)
PHP 28,500.36
(inc. VAT)
units
Per Unit
1 +
PHP25,446.75
Related Products
The samosPRO Compact is suitable for monitoring non-contact ...
Description:
The samosPRO Compact is suitable for monitoring non-contact safety sensors, emergency off buttons, protective door switches and door closures, two-hand controls as well as testable safety light barriers, light curtains and laser scanners. Not only is it suitable for use ...
The PNOZ ml1p module is used for the ...
Description:
The PNOZ ml1p module is used for the safe connection of two PNOZmulti safety systems. Can be configured in the PNOZmulti ConfiguratorPoint-to-point connection via 4-core shielded twisted-pair cable32 virtual inputs and 32 virtual outputsStatus indicatorsPlug-in connection terminalsMaximum of 4 PNOZ ...
The PNOZ m EF Multi Link Module safely ...
Description:
The PNOZ m EF Multi Link Module safely connects two PNOZmulti 2 base units. Connects two PNOZmulti 2 base units Can be configured in the PNOZmulti ConfiguratorPoint-to-point connection via 4-core shielded and twisted-pair cable32 virtual inputs and 32 virtual outputsStatus ...
Professional range of IDEM VIPER Safety Relays with ...
Description:
Professional range of IDEM VIPER Safety Relays with pluggable and screw terminals. The safety relays incorporate expansion units. The relays can be directly wired to increase the number of safety output contacts. Designed to meet the latest safety standard and ...