Siemens S7-200 Series PLC CPU for Use with SIMATIC S7-200 Series, Digital, Relay Output, 24 (Digital)-Input, Digital
- RS Stock No.:
- 488-6656
- Mfr. Part No.:
- 6ES7216-2BD23-0XB0
- Manufacturer:
- Siemens
Discontinued product
Alternative
This product is not currently available. Here is our alternative recommendation.
- RS Stock No.:
- 488-6656
- Mfr. Part No.:
- 6ES7216-2BD23-0XB0
- Manufacturer:
- Siemens
Legislation and Compliance
RoHS Status: Not Applicable
Product Details
Siemens S7-226 CPU
40 on board I/O
24kbytes of programme memory
10kbytes of data memory
6 x 30kHz high speed counter
2 x RS-485 comms interfaces
In-built real time clock
4 x 20kHz pulse train outputs (dc powered model only)
24kbytes of programme memory
10kbytes of data memory
6 x 30kHz high speed counter
2 x RS-485 comms interfaces
In-built real time clock
4 x 20kHz pulse train outputs (dc powered model only)
Note
Siemens PLC CPU
The Siemens PLC CPU is ideal for the faster type of applications as real-time control is easily achieved by using the comprehensive range of built-in interrupts that has a voltage rating of 24VDC. It has a compact design with 24 integrated digital inputs and 16 integrated digital outputs output of 2A contact current rating. Timer, communication, high-speed counter, high-speed pulse output and hardware interrupts are all available. The implementation of a priority table means that all the interrupts can work simultaneously. Communication with S7-200 has various built-in interfaces. Inter PLC communication is achieved by using a two-wire network, which can be up to 1200m and can have up to 126 nodes. In Freeport mode, the PLC's RS-485 port runs in free ASC11 mode, making it possible to communicate with other devices. In line with Siemens objective to make the programming of S7-200 user-friendly, MicroWin programming software has been further improved. These improvements help to minimise program development time. This has been achieved by including more and improving the existing 'wizards'. These help program developers with the more routine/complex parts of their programs, e. G. TD200 configuration, PID loop configuration, high-speed counter configuration, etc. Inclusion of context-sensitive help also means that all the information required is at the fingertips.
Note:
Output rating is 28.8VDC maximum for transistor outputs (stock no. 488-6662)
Note:
Output rating is 28.8VDC maximum for transistor outputs (stock no. 488-6662)
30VDC or 240VAC maximum for relay outputs (stock no. 488-6656)
Features and Benefits
• New CPU hardware support provides the option to turn the running mode edit to obtain more program memory
• CPU 226 includes additional input filters and pulse catch facility
• 0.22μs processing time per instruction
• Maximum expansion units possible are 7
• Powerful instruction set
• Real-time performance
• Programming is via RS-485 communication port
• It has EEPROM memory for user program storage
• 2 x 30kHz pulse train outputs
• 2 integrated analogue inputs
• 2 integrated analogue outputs
• Communication protocols like MPI, PPI and RS485 available
• Operation temperature ranges between 0°C and 45°C
• CPU 226 includes additional input filters and pulse catch facility
• 0.22μs processing time per instruction
• Maximum expansion units possible are 7
• Powerful instruction set
• Real-time performance
• Programming is via RS-485 communication port
• It has EEPROM memory for user program storage
• 2 x 30kHz pulse train outputs
• 2 integrated analogue inputs
• 2 integrated analogue outputs
• Communication protocols like MPI, PPI and RS485 available
• Operation temperature ranges between 0°C and 45°C
Applications
•
Industrial automation
• Robotics
• Automobiles industry
Industrial automation
• Robotics
• Automobiles industry
Certifications
•
IP20 rated
IP20 rated
Warning
This product is in obsolescence mode and is due for discontinuation by the manufacturer. We recommend that you review the alternative highlighted by the manufacturer. Alternatively, refer to the cross reference list in the Technical Reference section which highlights the upgrade path for your current generation of products.
Siemens S7-200 Base Units - 3rd Generation
The S7 brings to the user a powerful solution to a host of control applications, which is easy to adapt and expand the system. The S7 is a family of PLCs which allows the user to tailor their selection of components which best suits their requirements, and is the long term successor to the highly successful S5 range. Whatever the S5 can do, the S7 can do more quickly and more easily. The 3rd generation of S7-200 now builds on the success of the original range and exploits new CPU's in order to produce even faster and more powerful range of PLC's. The range of CPU's available has been increased with the introduction of the new 224XP, as has the range of digital, analogue and communications expansion modules. For the faster type of application real time control is easily achieved by use of the comprehensive range of built-in interrupts. Timed, Communication, High Speed Counter, High Speed Pulse Output, and hardware interrupts are all available, and the implementation of a priority table means that all the interrupts can work simultaneously. Communications with S7-200 is built in. Inter PLC communications is achieved using two wire network which can be up to 1200 meters and can have up to 126 nodes. In "Freeport" mode the PLC's RS-485 port runs in free ASC11 mode making it possible to communicate with other devices. In line with Siemens objective to make the programming of S7-200 as user friendly as possible MicroWin programming software has been further improved. These improvements all help minimise program development time. This has been achieved by including more and improving existing "wizards". These help program developers with the more routine/complex parts of their programs, e.g. TD200 configuration, PID loop configuration, High Speed Counter configuration, etc. Inclusion of context sensitive help also means that all the information required is at the users fingertips.
New CPU hardware support provides the option to turn off run mode edit to obtain more program memory
CPU 224XP supports onboard analogue I/O and two communication ports
CPU 226 includes additional input filters and pulse catch facility
0.22μs processing time per instruction
CPU 224XP supports onboard analogue I/O and two communication ports
CPU 226 includes additional input filters and pulse catch facility
0.22μs processing time per instruction
Modular Expansion up to 256 total I/O (except S7-221)
Powerful Instruction Set, and Real Time performance
Programming via RS-485 comms port
All models have EEPROM memories for user program storage
2 or 4 x 30kHz pulse train outputs (dc powered models only )
Powerful Instruction Set, and Real Time performance
Programming via RS-485 comms port
All models have EEPROM memories for user program storage
2 or 4 x 30kHz pulse train outputs (dc powered models only )
Specifications
Attribute | Value |
---|---|
Manufacturer Series | S7-200 |
Number of Inputs | 24 (Digital) |
Output Type | Digital, Relay |
For Use With | SIMATIC S7-200 Series |
Input Type | Digital |
Number of Outputs | 16 (Digital) |
Voltage Category | 120 V ac, 230 V ac |
Minimum Operating Temperature | 0°C |
Dimensions | 80 x 196 x 62 mm |
Communication Port Type | RS485 |
Width | 196mm |
Output Current | 2 A |
Programming Interface | Computer, SIMATIC PG/PC |
Memory | 10 (Data Memory) kB, 24 (Program Memory) kB |
Programming Language Used | AWL, FUP, Ladder Logic |
Maximum Operating Temperature | +45°C |
Number of Communication Ports | 2 |
Mounting Type | Rack Mount |
Length | 80mm |
Depth | 62mm |
Program Capacity | 24 kB |
Battery Backup | Yes |