2 x 12V ac 2 Output PCB Mount PCB Transformer, 2.3VA

  • RS Stock No. 121-3829
  • Manufacturer RS PRO
Technical data sheets
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): CN
Product Details

RS Pro PCB Standard Transformers

RS Pro PCB Standard transformers are low voltage mains transformers with a single 230 VAC 50/60Hz primary winding
These transformers have secondary windings suitable for series/ parallel connection to give a wide range of current options. They are 100% electric and flash tested. Double section bobbin, high efficiency and low temperature rise. These RS Pro transformers have low interwinding capacity and low radiated noise.

Specifications
Attribute Value
Secondary Voltage Rating 2 x 12V ac
Power Rating 2.3VA
Primary Voltage Rating 230V ac
Number of Outputs 2
Length 32.5mm
Width 27.5mm
Depth 29.5mm
Dimensions 32.5 x 27.5 x 29.5mm
Weight 110g
Mounting Type PCB Mount
Maximum Temperature +130°C
Minimum Operating Frequency 50Hz
Maximum Operating Frequency 60Hz
32 In Global stock for delivery within 4 - 8 working days
Price Each
PHP 273.92
(exc. VAT)
PHP 306.79
(inc. VAT)
units
Per Unit
1 - 9
PHP273.92
10 +
PHP264.57
Related Products
Chassis mounting frame construction low voltage mains transformers ...
Description:
Chassis mounting frame construction low voltage mains transformers with a single 230Vac 50/60Hz primary winding. This range of single-phase single-winding safety and isolation transformer is primarily designed for use in repetitive applications.ABT 7 series transformers provide enhanced electrical isolation ...
Chassis mounting frame construction low voltage mains transformers ...
Description:
Chassis mounting frame construction low voltage mains transformers with a single 230Vac 50/60Hz primary winding. Single-phase single-winding safety and isolation transformers.Able to supply higher powers on occasion.Feature a panel display to reduce ESD. Screw termination.Plate mounting.
Secondary voltages are nominal load voltages on resistive ...
Description:
Secondary voltages are nominal load voltages on resistive loads.Only the pins indicated on the wiring diagram "physically" exist.
Twin 115Va.c. 50 to 60Hz primary windings for ...
Description:
Twin 115Va.c. 50 to 60Hz primary windings for series or parallel connectionTwin secondary windings for series or parallel connectionLow profile compact designVacuum epoxy resin moulded to UL94-V0 ratingDouble section glass fibre reinforced polyamide bobbins100% electrical and flash testedLow inter-winding ...