ABB 5 A Motor Load Monitor, 380 → 415 V, -10 → +60 °C

  • RS Stock No. 285-4607
  • Mfr. Part No. PAIR400L000
  • Manufacturer ABB
Technical data sheets
Legislation and Compliance
RoHS Status: Not Applicable
Product Details

PAIR Motor Protection Relay

The PAIR module is designed for use with induction motors that require protection against both overload and underload conditions.

Overcurrent sensing with inverse time delay response
Sensitive underload protection by power factor measurement
Integral current transformer up to 32A
Current range can be extended with external current transformers
Adjustable start up and reset delays
Permanent memory of tripped status in the event of power loss
Indicator lamps for supply and tripped conditions
Reset can be automatic, manual and both local and remote
IP20 enclosure DIN rail mounting
Typical applications include protection against dry pumping for submersible pumps

Specifications
Attribute Value
Motor Protection System PAIR
Motor Protection Component Load Monitor
Sensing Type Current Transformer
Supply Voltage 380 → 415 V
Current Rating 5 A
Minimum Operating Temperature -10°C
Maximum Operating Temperature +60°C
2 In Global stock for delivery within 4 - 8 working days
Price Each
PHP 43,037.12
(exc. VAT)
PHP 48,201.57
(inc. VAT)
units
Per Unit
1 +
PHP43,037.12
Related Products
The network-capable 3-phase hybrid motor starter with reversing ...
Description:
The network-capable 3-phase hybrid motor starter with reversing function and current monitoring The amount of cabling required is reduced to a minimum by the internal locking circuit and the load wiring. The control commands for backward and forward running are ...
The Altivar ATV12 Series is made up from ...
Description:
The Altivar ATV12 Series is made up from Variable Speed Drives for small machines with a three-phase 240 V 0. 18 to 4 kW asynchronous motors. This type of VFD has a low voltage, high performance and excellent power. The ...
Quantifying the status of a three-phase induction motor ...
Description:
Quantifying the status of a three-phase induction motor and pump. The alarm output threshold default is set. You can customize the value according to the site. As for comprehensive current diagnosis, the degradation can be detected comprehensively by combining each ...
Units which measure true motor load in kW ...
Description:
Units which measure true motor load in kW featuring a digital display of kW% and programmable trips for over and/or under load events.These units protect equipment from damage caused by the motor running against a jam, blockage or under load ...