XY2-CE Cable Switch, Left Side, 50m, NO/NC

Technical data sheets
Legislation and Compliance
RoHS Status: Not Applicable
COO (Country of Origin): MA
Product Details

Telemecanique XY2CE & XY2CB Emergency Stop Rope Pull Switches

These emergency stop trip wire switches are designed to reduce the risk of injury to persons and damage either to machines or work in progress. They can be tripped by a single human action when a normal emergency stop function is not available and will also trip in the event of the trip wire breaking.

Switches incorporate positive opening operation contacts, the tripping of the switch being made with positive action
The switch latches in the tripped position (N/C safety contact(s) open). The function of the N/O contact is purely for signalling
Incorporates a reset button, which re-closes the safety contact(s), restarting of the machine must only be achieved by manual operation of a control device within the machine start circuit, remote to the trip wire switch
Recommended distance between cable supports is 15m (for model XY2-CB30 a distance of 20m is recommended)
The XY2 CE1A296 comes with a pilot light (direct supply)

Note

The XY2 CB switch must not be used if the installation requires that the trip wire be angled but the XY2 CE switch can. In this case, the total sum of the angles through which the trip wire bends must not exceed 180°.

Standards

EN/ISO 13850:2006

Specifications
Attribute Value
Range Preventa
Series XY2-CE
Reset Button Yes
Normal State Configuration NO/NC
Mounting Orientation Left Side
Maximum Rope Span 50m
Maximum Current 10 A
Maximum AC Voltage 300V
Number of Cable Entries 3
Size of Cable Entries 0.5 in NPT
Depth 4.1in
Dimensions 5.6 x 7.8 x 4.1 in
E-Stop Button No
Length 5.6in
Width 7.8in
1 In Global stock for delivery within 4 - 8 working days
Price Each
PHP 16,578.04
(exc. VAT)
PHP 18,567.40
(inc. VAT)
units
Per Unit
1 +
PHP16,578.04
Related Products
1. Operation of pedal up to pressure point:the ...
Description:
1. Operation of pedal up to pressure point:the work contact is closed and the work process is initiated.2. In an emergency situation, operate beyond the pressure point resistor:The work contact is stopped and locked and the work process is stopped. ...
Telemecanique XY2CE EX ATEX emergency stop rope pull ...
Description:
Telemecanique XY2CE EX ATEX emergency stop rope pull switches are designed to reduce the risk of injury to persons and damage either to machines or work in progress. They can be tripped by a single human action when a normal ...
The Telemecanique sensors XY2CE is 240VAC voltage wire ...
Description:
The Telemecanique sensors XY2CE is 240VAC voltage wire switch. It has E-stop rope pull switch on right side-2NC+2NO with yellow pilot light, 230V-boot. • Contact operation slow break• Cover material is stainless steel• Housing material is Zamak• Maximum rope span ...
The 3SE7 series of grab wire switches (trip ...
Description:
The 3SE7 series of grab wire switches (trip wire switches, cable operated switches) are used for monitoring or for EMERGENCY STOP devices on particularly dangerous system sections.As the effective range of a grab wire switch is only limited by the ...