HOBUT CT196, Base Mounted Current Transformer, , 45mm diameter , 800:5

  • RS Stock No. 381-0793
  • Mfr. Part No. CT196M800/5-5/1
  • Manufacturer HOBUT
Technical data sheets
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): GB
Product Details

Base/Busbar Mounting Current Transformer

Moulded case with sliding sealable terminal covers
Operating temperature range –30 to +85°C
Screw or push on terminal connectors
Secondary terminals M5 studs with washers, lock washers and nuts
Narrow width allows close mounting between busbars
Insulation voltage 0.72/3kV
125 x 66 x 90mm (H/W/D)
50mm aperture suitable for circular conductors
Protection to IP20
Conforms to IEC44-1, IEC 185 and BS7626
CE Marked in compliance with relevant European Directives

Current Transformers

Specifications
Attribute Value
Current Ratio 800:5
Bore Size 45mm
Transformer Type Base Mounted
Overall Height 126mm
Overall Width 90mm
Overall Depth 60mm
Minimum Temperature -30°C
Maximum Temperature +85°C
Series CT196
Mounting Type Base Mounted
4 In Global stock for delivery within 4 - 8 working days
Price Each
PHP 1,340.60
(exc. VAT)
PHP 1,501.47
(inc. VAT)
units
Per Unit
1 - 4
PHP1,340.60
5 - 9
PHP1,307.22
10 +
PHP1,272.95
Related Products
Power consumption 2.5VA, 50/60HzAccuracy class 120 or 30mm ...
Description:
Power consumption 2.5VA, 50/60HzAccuracy class 120 or 30mm busbar mountingSuitable for circular conductors 24 apertureMaximum aperture for bar conductors 30x10mm (type 6)Operating temperature range –30 to +85°CSecondary terminals M5 studs with lock washers, nuts and terminal coverFull scale deflection currents ...
A range of compact moulded case current transformers ...
Description:
A range of compact moulded case current transformers suitable for primary currents from 30A to 800A with built-in sealable terminal covers. For transforming various primary currents into,5A standard secondary using 20/30/40mm busbars or cables, or 28mm cables. Built-in sealable terminal ...
Three phase measuring current transformers suitable for primary ...
Description:
Three phase measuring current transformers suitable for primary ranges from 60A to 630A with 5A secondary. Allowing installations directly next to the moulded case circuit breakers for greater speed of installation and optimisation of space. Applicable to MCCB such as ...
Used for measuring higher currents with the EQN ...
Description:
Used for measuring higher currents with the EQN moving-iron instrumentsSecondary voltage designed for 5 AConnects directly to display instruments with a 5 / 10 A current pathFor connection to cables or power railsLead-sealableExtremely fire-resistant housing, self-extinguishing in accordance with UL94-VOIncl. ...