ABB CMS Series Current Sensor, 80A

  • RS Stock No. 833-2879
  • Mfr. Part No. CMS-100S8
  • Manufacturer ABB
Technical data sheets
Legislation and Compliance
RoHS Certificate of Compliance
Product Details

ABB Circuit Monitoring System CMS

Circuit Monitoring Systems (CMS) are multichannel measurement systems for branch monitoring of electrical installations. Each system consists of a Control Unit and sensors with different measurement ranges and mounting possibilities. The systems can be installed easily within power distribution units. Due to the unique compact size, the system is also ideal as a retrofit solution for existing installations. Great importance has been placed on user friendliness, high accuracy and a wide measurement range (up to 160 A).

CMS-600 Supply- and Control Centre
Supplied as a unit with flat cable & connector set
Illuminated touch display
Intuitive menu navigation
Supply voltage 24 Vdc
Measure AC and DC currents up to 64 individual lines via CMS-Bus (4-wire flatcable)
Measured data can be remotely queried by a 2-wire RS-485 interface
RTU Modbus, Data rate 2400-115200 Baud
DIN Rail Mounting

Specifications
Attribute Value
Nominal Current 80A
Supply Voltage 690 V ac, 1500 V dc
Sensor Type CMS Sensor
Mounting Type Cable Mount
Frequency Bandwidth 50/60 Hz
Bore Size 10mm
Accuracy ±0.7 %
Series CMS
Minimum Operating Temperature -25°C
Maximum Operating Temperature +70°C
Depth 45.5mm
Height 31.8mm
Width 45.5mm
Temporarily out of stock - back order for despatch 03/11/2020, delivery within 6 working days from desptach date
Price Each
PHP 4,683.14
(exc. VAT)
PHP 5,245.12
(inc. VAT)
units
Per Unit
1 - 4
PHP4,683.14
5 - 9
PHP4,601.24
10 +
PHP4,481.66
Related Products
Open loop current transducerHall effect measuring principleFor measuring ...
Description:
Open loop current transducerHall effect measuring principleFor measuring DC, AC and pulse currentsGalvanic isolation between primary and secondary circuitsHousing made from insulating, self-extinguishing material UL94-V0.
Linear current sensors from Honeywell incorporating LOHET II ...
Description:
Linear current sensors from Honeywell incorporating LOHET II Hall effect transducers. These devices have increased temperature stability and 10 times less temperature drift than the LOHET I types and produce a ratiometric output voltage that varies from 19% to 81% ...
Sifam Tinsley Theta 20A/20V compact programmable transducers measure ...
Description:
Sifam Tinsley Theta 20A/20V compact programmable transducers measure and convert AC voltage or current input into a load independent DC output signal. Featuring an LCD display and are on-site configurable. True RMS measurement On-site programmable inputs On-site selectable output: DC ...
AC / DC transformer with integrated signal preparationMeasures ...
Description:
AC / DC transformer with integrated signal preparationMeasures currents with VFD and SCR wavelengthElectrical isolationActual output; voltage or currentNo excess lossesCable entry to 32 mm ØSimple installation.