Phoenix Contact MCR-SLP-1-5-UI-0 Series Current Sensor, 0 → 5A, 0 → 20mA output current

Technical data sheets
Legislation and Compliance
Non Compliant
COO (Country of Origin): DE
Product Details

Current Transducer, MCR-SLP

The 2814359 from Phoenix Contact is an MCR passive current measuring transducer used for sinusoidal alternating currents. This transducer can convert AC into analogue signals ranging from 1-20mA or 0-10 V. The module is powered purely through the loop, so no need for any external power. With being loop-powered, this device also mounts on a DIN rail, making it a great addition to your cabinet, making it effortless to convert into analogue signals. Not to mention, 2814359 also has great accuracy with its transmission error only at 0.5%.

Features and benefits:

Passive current transformers without auxiliary power
Convert ac into analogue signals 1 to 20mA or 0 to 10V
Limit monitor
Limit value and alarm suppression time set by two potentiometers
1 NO, 1NC relay contact

Specifications
Attribute Value
Nominal Current 0 → 5A
Output Current Range 0 → 20mA
Mounting Type Chassis Mount
Frequency Bandwidth 45 → 60 Hz
Accuracy <0.5 %
Series MCR-SLP-1-5-UI-0
Minimum Operating Temperature -25°C
Maximum Operating Temperature +60°C
Depth 114.5mm
Height 99mm
Output Voltage Range 0 → 10V
Width 22.5mm
2 In stock for delivery within 4 working days
Price Each
Was PHP14,523.65
PHP 13,634.42
(exc. VAT)
PHP 15,270.55
(inc. VAT)
units
Per Unit
1 +
PHP13,634.42
Related Products
Current sensors with rectangular split core..Measurement of direct, ...
Description:
Current sensors with rectangular split core..Measurement of direct, alternating and pulse current with galvanic insulation.Connection using Molex 5045-04/AG connector.Compact size.Hole diameter: 21 mm.
Sifam Tinsley Theta Hz programmable transducer is used ...
Description:
Sifam Tinsley Theta Hz programmable transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or DC Voltage. On-site programmable inputs On-site selectable output: DC Current or DC Voltage ...
The optional holding device ensures the Rogowski coil ...
Description:
The optional holding device ensures the Rogowski coil is securely seated on busbars that are 5 ... 10 mm thick. During installation, the coil housing is pushed onto the flange of the holding device and snaps in automatically.
AC / DC transformer with integrated signal preparationMeasures ...
Description:
AC / DC transformer with integrated signal preparationMeasures currents with VFD and SCR wavelengthElectrical isolationActual output; voltage or currentNo excess lossesCable entry to 32 mm ØSimple installation.