Schneider Electric Overload Relay - NO/NC, 0.3 → 1.5 A F.L.C, 1.5 A Contact Rating, 55 W

Technical data sheets
Legislation and Compliance
RoHS Status: Not Applicable
Product Details

LR97 D Electronic Overcurrent Relays

Suitable for machine protection requirements where machinery may be subject to difficult starting, jamming, high resistive torque/high inertia and/or mechanical failure
1 N/O and 1 N/C contact
LED status indication: Voltage, Starting, Steady State, Overload, Trip
Trip status monitored: Over-Current, Rotor Locked, Phase Failure (L1, L2, L3)
Manual or automatic reset
H 64.5mm x W 45mm x D 67.5mm

Note

Current range (A) refers to the relay setting range. To allow for tripping sensitivity, the useable current range will be less than the maximum value quoted. Please refer to the manufacturer’s data sheet for specific product information.

Specifications
Attribute Value
FLC Motor Rating 0.3 → 1.5 A
Contact Current Rating 1.5 A
Range TeSys
Contact Voltage Rating 690 V ac
Mounting Style Direct Contactor
Supply Voltage 200 → 240 V ac
Series LR97 D
Normal State Configuration NO/NC
Number Of Auxiliary Contacts 2
Power Rating 55 W
Reset Method Automatic, Manual
Terminal Type Screw
Length 64.5mm
Width 45mm
Depth 67.5mm
Minimum Operating Temperature -25°C
Operating Temperature Range -25 → +60 °C
Maximum Operating Temperature +60°C
3 In Global stock for delivery within 4 - 8 working days
Price Each
PHP 6,147.69
(exc. VAT)
PHP 6,885.41
(inc. VAT)
units
Per Unit
1 +
PHP6,147.69
Related Products
The 3RU21 thermal overload relays up to 80 ...
Description:
The 3RU21 thermal overload relays up to 80 A have been designed for current-sensitive protection of loads with normal starting.These thermal overload relays for use with Sirius Size S0 & S00 Contactors. Switch position indicator and test functionSTOP buttonSelector switch ...
Type RF38, phase failure sensitive, manual or automatic ...
Description:
Type RF38, phase failure sensitive, manual or automatic resettingType RFN38, non phase failure sensitive, manual or automatic resettingType RF82 and RF95, phase failure sensitive, manual resettingType RFA82 and RFA95, phase failure sensitive, automatic resettingType RFN82 and RFN95, non phase failure ...
Relays may be used with an ac or ...
Description:
Relays may be used with an ac or dc supply. 1 x NO and 1 x NC contact. Trip fault indication. Manual or auto reset button. For more data, see Telemecanique TeSys D Range Contactors/Accessories. Trip Class 10A.
3RB30 and 3RB31 solid-state overload relays up to ...
Description:
3RB30 and 3RB31 solid-state overload relays up to 80 A with internal power supply have been designed for current-sensitive protection of loads with normal and heavy starting against excessive temperature rises due to overload, phase unbalance or phase failure. Switch ...