Schneider Electric Overload Relay NO/NC, 100 VA, 115 V ac

Technical data sheets
Legislation and Compliance
RoHS Status: Not Applicable
COO (Country of Origin): FR
Product Details

Schneider Electric LT3-S Range

Can be used with all motors equipped with PTC thermistor probes. It monitors windings temperature and ensures that the rated operating value is not exceeded, therefore guarding against faults which are often the cause of premature ageing. They can also be used to monitor surface temperature.

Automatic or manual reset
Remote reset
Fault storage with the supply switched off
Fault indication
Test function

Specifications
Attribute Value
Control Voltage 115 V ac
Range TeSys
Contact Voltage Rating 250 V ac
Series LT3S
Normal State Configuration NO/NC
Number Of Auxiliary Contacts 2
Power Rating 100 VA
Reset Method Automatic
Terminal Type Cage Clamp
Width 22.5mm
Length 100mm
Depth 100mm
Maximum Operating Temperature +60°C
Minimum Operating Temperature -25°C
Operating Temperature Range -25 → +60 °C
6 In Global stock for delivery within 4 - 8 working days
Price Each
PHP 10,272.08
(exc. VAT)
PHP 11,504.73
(inc. VAT)
units
Per Unit
1 - 5
PHP10,272.08
6 +
PHP10,126.90
Related Products
The ATEX approved, ELR series of Contractron 4 ...
Description:
The ATEX approved, ELR series of Contractron 4 in 1 hybrid motor starters from Phoenix Contacts give you an alternative to the traditional mechanical contractor circuits.The highly functional, DIN Rail mounting, reversing starter can be used where a three-phase induction ...
Suitable for machine protection requirements where machinery may ...
Description:
Suitable for machine protection requirements where machinery may be subject to difficult starting, jamming, high resistive torque/high inertia and/or mechanical failure1 N/O and 1 N/C contactLED status indication: Voltage, Starting, Steady State, Overload, TripTrip status monitored: Over-Current, Rotor Locked, ...
Suitable for remote machine protection requirements where machinery ...
Description:
Suitable for remote machine protection requirements where machinery may be subject to difficult starting, jamming, high resistive torque/high inertia and/or mechanical failure1 N/O and 1 N/C contactLED status indication: Voltage, Starting, Steady State, Overload, TripManual or electric resetH 67.5mm x ...
3RB30 and 3RB31 solid-state overload relays up to ...
Description:
3RB30 and 3RB31 solid-state overload relays up to 80 A with internal power supply have been designed for current-sensitive protection of loads with normal and heavy starting against excessive temperature rises due to overload, phase unbalance or phase failure. Switch ...