RS PRO 6VA 2 Output Chassis Mounting Transformer, 20V ac

  • RS Stock No. 504-789
  • Manufacturer RS PRO
Technical data sheets
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): PL
Product Details

Chassis Mount, Clamp Construction, 230Vac, 6VA to 50VA

Chassis mounting low voltage mains transformers with a single 230Va.c. 50/60Hz primary winding. The two independent secondary windings may be connected in series or parallel to give a wide range of output voltage and current options.

Double section bobbin construction
Fully shrouded bobbins
Full varnish impregnation
Two hole fixing wrap-over clamps
Solder tag terminations
Optional terminal shrouds
(example 503-912 )
100% electrical and flash tested
Tested in accordance with BS3535 and EN 60 742

Insulation Class B (130°C)
Isolation Primary to Secondary 4kV
  Windings to Core 2kV
  Primary/Secondary/Core 500Vdc
Max. Winding Temperature Rise +55°C ambient max.

Standards

BS3535; EN 60 742

Specifications
Attribute Value
Primary Voltage Rating 230V ac
Secondary Voltage Rating 20V ac
Power Rating 6VA
Number of Outputs 2
Mounting Type Clamp Mount
Length 45mm
Width 40mm
Depth 37mm
Dimensions 45 x 40 x 37mm
Fixing Hole Diameter 4 x 5.5mm
Weight 200g
Minimum Operating Frequency 50Hz
Maximum Operating Frequency 60Hz
54 In Global stock for delivery within 4 - 8 working days
Price Each
PHP 262.01
(exc. VAT)
PHP 293.45
(inc. VAT)
units
Per Unit
1 - 9
PHP262.01
10 - 24
PHP248.91
25 - 49
PHP236.47
50 - 99
PHP229.37
100 +
PHP227.66
Related Products
Chassis mounting mains transformers with twin 115Va.c. 50/60Hz ...
Description:
Chassis mounting mains transformers with twin 115Va.c. 50/60Hz primary windings which may be connected in series for 230V or parallel for 115V operation. The two independent secondary windings may be connected in series or parallel to give a wide range ...
Secondary voltages are nominal load voltages on resistive ...
Description:
Secondary voltages are nominal load voltages on resistive loads.Only the pins indicated on the wiring diagram "physically" exist.
Single and twin secondary windings for series or ...
Description:
Single and twin secondary windings for series or parallel connectionVacuum resin moulded to UL94-V0 ratingLow inter-winding capacitanceLow radiated noise100% electrical and flash testedExtra fixing points for secure board mounting (25 VA and 36 VA).
230Va.c. 50 to 60Hz primarySingle or twin secondary ...
Description:
230Va.c. 50 to 60Hz primarySingle or twin secondary windings for series or parallel connection (For conformance reasons,0.35 to 3.2VA transformers with 2 x 15 and 2 x 18V outputs and all transformers with 2x 24V outputs should not have their ...