Cooper Bussmann, 125A, British Standard Fuse, 7.2kV

Technical data sheets
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): GB
Product Details

Cooper Bussmann Motor Start Fuse Links

Cooper Bussmann range of motor fuse links are designed to meet the specific requirements necessary for motor protection. During the starting cycle of direct on-line motors, the fuse elements will reach a considerably higher temperature than during normal operation. Bussmann motor fuse links operate extremely quickly under heavy fault currents, resulting from the time / current characteristic. Low power dissipation ensures low temperature rise, important in multi-tier starters.

Cooper Bussmann

Specifications
Attribute Value
Current Rating 125 A
Voltage Rating 7.2 kV
Fuse Standard BS 2692
Fixing Centres 454mm
Tag Width 64mm
Overall Length 486mm
Body Diameter 76mm
Body Height 403mm
Temporarily out of stock - back order for despatch 20/10/2020, delivery within 6 working days from desptach date
Price Each
PHP 99,112.36
(exc. VAT)
PHP 111,005.84
(inc. VAT)
units
Per Unit
1 +
PHP99,112.36
Related Products
Semiconductor fuse links have a precise pre-determined performance ...
Description:
Semiconductor fuse links have a precise pre-determined performance which ensures a low arc voltage and minimum let through current. Semiconductor fuses are suited to application in the field of traction, distribution of power, motor drives and in process industries. Melt ...
Semiconductor fuse links have a precise pre-determined performance ...
Description:
Semiconductor fuse links have a precise pre-determined performance which ensures a low arc voltage and minimum let through current. Semiconductor fuses are suited to application in the field of traction, distribution of power, motor drives and in process industries. Melt ...
Die geschraubte Sicherung der Eaton Bussmann-Serie ist im ...
Description:
Die geschraubte Sicherung der Eaton Bussmann-Serie ist im Wesentlichen eine Sicherung mit Halterungen, mit denen die Sicherung auf einen Sicherungshalter geschraubt werden kann. Diese Art von Sicherung wird hauptsächlich in Anlagen als "Schwachstelle" verwendet. Sie sind so konzipiert, dass sie ...
As the fuse allows for the starting surge ...
Description:
As the fuse allows for the starting surge of a motor its full load current must not exceed the lesser of the dual current rating. e.g. 20 M25 must not have a continuous load of greater than 20A. Breaking capacity ...