Thermal Magnetic Circuit Breakers

Thermal magnetic circuit breakers are devices that provide protection against overcurrent in circuits. Circuit breakers use an automatically operated electrical switch to disrupt the flow of current when an overload or short circuit is detected. Thermal magnetic circuit breakers do this using an electromagnet and bimetallic strips. 


Circuit breakers provide more sophisticated protection against overcurrent than a simple fuse. Fuses simply burn out and have to be replaced, whereas circuit breakers just need to be reset.


How do thermal magnetic circuit breakers work?

In thermal magnetic circuit breakers, there are two ways the flow of current might be detected and disrupted. In the event of a short circuit, the electromagnet rapidly trips the switch. If the overload is smaller, over a longer period of time, the bimetallic strips will instead eventually react to trip the switch. 


What are thermal magnetic circuit breakers used for?

Thermal magnetic circuit breakers are most often used in distribution boards. They make up part of the subsidiary circuits in the broader electrical supply system, protecting against overcurrent.


...
Read more Read less

Filters

Viewing 1 - 20 of 2054 products
Results per page
Description Price Current Rating Number of Poles Range Voltage Rating Width Series Application Break Time Breaking Capacity at Maximum Voltage Rating Circuit Breaker Type Mounting Hole Diameter Mounting Hole Length Mounting Hole Size Mounting Hole Width
RS Stock No. 774-0042
BrandRS PRO
PHP191.28
Each
units
5A - - - 14.1mm A-0709 - - - - - - - -
RS Stock No. 774-0099
BrandRS PRO
PHP216.30
Each
units
2.2A 2 - 250V ac 6mm AN - - - - - - - -
RS Stock No. 774-0045
BrandRS PRO
PHP184.31
Each
units
6A - - 32 V dc, 240 V ac 14.1mm A-0709 - - - - - - - -
RS Stock No. 774-0020
BrandRS PRO
PHP336.19
Each
units
8A - - - 11mm A-0709 - - - - - - - -
RS Stock No. 774-0051
BrandRS PRO
PHP336.19
Each
units
9A - - - 14.1mm A-0709 - - - - - - - -
RS Stock No. 774-0039
BrandRS PRO
PHP336.19
Each
units
16A - - - 11mm A-0709 - - - - - - - -
RS Stock No. 774-0036
BrandRS PRO
PHP336.19
Each
units
13A - - - 11mm A-0709 - - - - - - - -
RS Stock No. 774-0067
BrandRS PRO
PHP193.87
Each
units
16A - - - 14.1mm A-0709 - - - - - - - -
RS Stock No. 774-0023
BrandRS PRO
PHP336.19
Each
units
9A - - - 11mm A-0709 - - - - - - - -
RS Stock No. 608-8769
Mfr. Part No.GV3ME80
PHP18,837.71
Each
units
- 3 TeSys 690V ac 61mm GV3M - - 100 kA - - - - -
RS Stock No. 272-921
Mfr. Part No.GV3P40
PHP14,402.87
Each
units
- 3 TeSys 690V ac 55mm GV3 - - 5 kA - - - - -
RS Stock No. 272-943
Mfr. Part No.GV3P50
PHP15,028.15
Each
units
- 3 TeSys 690V ac 55mm GV3 - - 5 kA - - - - -
RS Stock No. 782-7966
Mfr. Part No.W58-XC4C12A-15
PHP350.48
Each
units
15A 1 - 50 V dc, 250 V ac 0.66in W58 - - - - - - - -
RS Stock No. 272-937
Mfr. Part No.GV3P65
PHP12,935.53
Each
units
- 3 TeSys 690V ac 55mm GV3 - - 5 kA - - - - -
RS Stock No. 782-0892
Mfr. Part No.W58-XB1A4A-10
PHP311.19
Each
units
10A 1 - 50 V dc, 250 V ac 0.66in W58 - - - - - - - -
RS Stock No. 782-8026
Mfr. Part No.W58-XC4C12A-5
PHP350.48
Each
units
5A 1 - 50 V dc, 250 V ac 0.66in W58 - - - - - - - -
RS Stock No. 336-012
Mfr. Part No.106-P30-000040-1A
BrandETA
PHP554.91
Each
units
1A 1 - - 19mm 106-P30 - - - - - - - -
RS Stock No. 312-3825
Mfr. Part No.GB2DB10
PHP2,861.04
Each
units
5A 2 - 277 V ac, 415 V ac 30mm GB2 - - 1 (dc) kA, 2 (ac) kA - - - - -
RS Stock No. 312-3645
Mfr. Part No.GB2CB07
PHP1,142.06
Each
units
2A 1 - 277 V ac, 415 V ac 15mm GB2 - - 1 (dc) kA, 15 (ac) kA - - - - -
RS Stock No. 782-0911
Mfr. Part No.W28-XQ1A-3
PHP177.93
Each
units
3A 1 - 32 V dc, 250 V ac 0.76in W28 - - - - - - - -
Related Products
All-current-sensitive FI circuit breaker for detection of residual ...
Description:
All-current-sensitive FI circuit breaker for detection of residual AC currents, pulsating and smooth residual DC currentsIncreased operating reliability in networks with capacitive impedances based on adapted actuation characteristicSwitch handle and test button may be locked via handle lockTime-delayed disconnect ...
Acti9 iTG40 RCCBs limits wear and reduces voltage ...
Description:
Acti9 iTG40 RCCBs limits wear and reduces voltage drops, helping to prevent premature equipment aging and overheating. VisiTrip indicates only the faulty outgoer, allowing fast diagnosis, resolution, and re-closing loads for easier building management and reduced downtimeInsulation Voltage: 440 VacVoltage: ...
The Acti 9 iID DIN rail RCCBs, are ...
Description:
The Acti 9 iID DIN rail RCCBs, are fully coordinated with the iC60 MCBs to warranty an absolute people and equipment protection against electrocution, risk of fire and improved continuity of service. Protection of persons against electric shock by direct ...
Thanks to its new power terminals, this range ...
Description:
Thanks to its new power terminals, this range of GV3 magnetic circuit-breakers assures improved reliability of connections and is designed to maintain a constant tightening force which assures a strong, safe and long lasting connection in the most demanding environments. ...